SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Low generator output
voltage

Excitation capacitor failure

• Contact a qualified generator dealer for service assistance.

Generator diode or varistor
failure

• Contact a qualified generator dealer for service assistance.

Overspeed LED stays lit

Shutdown due to high engine
speed

• Verify correct engine speed setting.

Low Speed LED stays lit

Shutdown due to low engine
speed

• Reduce loads connected to generator.

Overcrank light stays lit

Failure to start

• See "Engine cranks without starting".

Low oil pressure LED
stays lit

Shutdown due to low engine
oil pressure

• Check engine oil level.

• Verify correct type of engine oil for ambient temperature
conditions.

Low battery LED stays lit Low battery

• Test battery. Replace as necessary.

• Ensure charger is plugged into receptacle.

• Check for tripped main circuit breaker. Reset if required.

• Check all charger cable connections for cleanness and
tightness.

• Check battery charger inline fuse.

• Check charger lights to verify correct operation. See Table
A, Page 26.

High temperature LED
stays lit

Shutdown due to high engine
temperature

• Allow engine to cool, then restart.

• Decrease loads on generator.

• Check enclosure openings for blockage.