After completing all installation procedures, read and

understand the operating instructions for the generator
controller. Know how the control panel operates, what to
expect when activating control panel switches and how
to shut the generator off in the event of an emergency.
Before starting the generator for the first time, check off
all items on the following list, then follow the given
procedure to verify correct operation of the generator.
‰ Is unit level?
‰ Is adequate free air space (3 feet minimumor

greater,check your local building codes for clearance
requirements for your area.
) available on all sides of
the enclosure?

‰ Are all cabinet openings free from blockage?
‰ Is the exhaust directed away from dwellings, dwelling

air intakes, or combustible materials?

‰ Are the fuel supply lines and internal generator fuel

connections leak-free?

‰ Is fuel supply pressure within specifications?
‰ Is the regulator connection properly configured for

the fuel supplied?

‰ Is an approved transfer switch used to prevent

backfeed into utility lines?

‰ Are electrical connections tight, and properly

connected?

‰ Are electrical conductors sized properly?
‰ Is a properly sized engine cranking battery correctly

installed?

‰ Is the battery maintenance charger plugged in and

operating correctly?

‰ Are all protective covers installed and tightened?
‰ Are all tools clear of moving or electrically live parts?
‰ Is the installation inspected and approved as

required by local or regional code?
Once all items on the checklist are marked off,

complete the initial startup using the listed steps.

1. Press the OFF button on the control panel of the

generator.

2. Move the main line circuit breaker handle on the

generator to the OFF position.

3. Check the utility, or preferred, power supply to the

transfer switch following the instructions provided by
the switch manufacturer.

4. Ensure utility power to the transfer switch is shut off.
5. Return to the generator and open any manual shutoff

valves in the fuel supply system.

6. Press the MANUAL button on the control panel. The

generator should crank and start.

7. Allow the generator to run for approximately three (3)

minutes, then move the main line circuit breaker
handle to the ON position.

8. Check across the circuit breaker of the main line

power output block (Red to Black) for proper
frequency and voltage. Frequency should read
approximately 62.5 Hz and voltage between 240 and
245 volts at no load conditions.

9. Adjust no load speed as required to meet

approximately 62.5 Hz.

10. Shut the generator down by pressing the OFF button

on the control panel.

11. Restore utility power to the transfer switch.
12. Press the AUTO button on the control panel to set

the generator to automatic.

13. Inspect the site to ensure no packaging or installation

materials remain within or against the generator.

14. Replace all covers on the generator.
15. Place the generator into service by pressing the

AUTO button on the control panel.

A standby generator is an engine driven air cooled

system to convert the energy contained in either liquid
propane vapor or natural gas to electrical power. When
coupled with an automatic transfer switch to monitor for
failure of utility power, the unattended system can start,
stop and transfer between sources to insure a nearly
seamless supply of power. The generator is housed in a
weather resistant, sound attenuated enclosure for
outdoor installation only.

Before installing and starting the generator, become

familiar with the controls and operational features of the
generator. Know how the control panel operates, what to
expect when activating control panel switches and how
to shut the generator off in the event of an emergency.

F

F

F

F

II

II

R

R

R

R

S

S

S

S

T

T

T

T

T

T

T

T

II

II

M

M

M

M

E

E

E

E

S

S

S

S

T

T

T

T

A

A

A

A

R

R

R

R

T

T

T

T

U

U

U

U

P

P

P

P

D

DA

AN

NG

GE

ER

R

Contact with high voltages present in
generators and utility systems can cause
severe electric shock or death. Avoid contact
with all live components.

Allow only qualified generator service
technicians or licensed electrician's to perform
initial system start-up.

D

DA

AN

NG

GE

ER

R

Generator is now supplying dangerous
voltages. Use extreme caution performing
electrical checks.

C

CA

AU

UT

TIIO

ON

N

Failure to set the controller to AUTO before
leaving the generator renders the generator
unavailable for automatic standby service.

G

G

G

G

E

E

E

E

N

N

N

N

E

E

E

E

R

R

R

R

A

A

A

A

T

T

T

T

O

O

O

O

R

R

R

R

O

O

O

O

P

P

P

P

E

E

E

E

R

R

R

R

A

A

A

A

T

T

T

T

II

II

O

O

O

O

N

N

N

N