beautypg.com

Opening preparation – Pella Clad Windows with Flush Flange 81CP0101 User Manual

Page 3

background image

1/4" minimum

Sealant

1F

Repeat steps C - E for all four sides of the opening.

F. Remove any debris, paint or stucco from the

exterior face of the existing window frame that will

interfere with the new window installation. Clean any

dirt or debris from the existing sill and ensure the

weep holes are open and clear.

D. Use pliers to remove the 2” section(s) of frame.

1D

1E

1G

E. Starting in the 2” frame notch, use a

reciprocating saw to cut the frame legs flush

with the drywall. Do not cut through the frame

exposing the rough opening. Do not damage

the drywall where it will remain exposed after

the new window is in place.
Note: At the sill, ensure that 1/4” minimum

height of frame leg remains to act as a sill dam.

G. Seal the existing jamb frame joints to the

sill of the existing aluminum window frame

with beads of sealant.

H. Seal any screw holes from the original

divider with sealant. DO NOT plug any weep

holes in the existing frame.

1F

1

OPENING PREPARATION