Panasonic Web-Server FP User Manual
Page 91

Http Server Functions/ Web Pages
FP Web-Server V2.11
80
Format
PLC value
Display
{DT201_6_+d} 12345
(3039hex)
"+12345"
b) Spaces and zeros
Format
PLC value
Display
{DT201_6_i }
DT201=17
"17 " (HTML suppresses multiple spaces)
{DT201_6_06i} DT201=17 "000017"
{DT201_6_ 6i}
DT201=17
" 17" (HTML suppresses multiple spaces)
{DT201_6_6.0i}
DT201=17
" 17" (HTML suppresses multiple spaces)
c) Hex
display
Format
PLC value
Display
{DT201_4_4X}
DT201=17
" 11" (HTML suppresses multiple spaces)
{DT201_4_04X}
DT201=17
"0011"
{DT202_8_08lX}
DDT202=123456
"0001E240" (lower case L before X)
{DT202_8_8lx}
DDT202=123456
"1e240" (lower case L before X)
d) Float (real value) display
Format
PLC value
Display
{DT202_8_f} DDT202=6.7
(40D66666hex)
"6.700000"
{DT202_8_7.2f} DDT202=12345
(4640E400hex)
"12345.00"
{DT202_8_7.2f} DDT202=23.456
(41BBA5E3hex)
" 23.46 "
{DT202_8_+7.2f} DDT202=1234.56
(449A51EChex)
"+1234.56"
{DT202_13_e} DDT202=123.4
(42F6CCCDhex)
"1.234000e+002"
{DT202_13_E} DDT202=1234000
(4996A280hex)
"1.234000E+006"
{DT202_10_g} DDT202=123.4
(42F6CCCDhex)
"123.4 "
{DT202_10_g} DDT202=1234000
(4996A280hex)
"1.234e+006"
e) Display
strings
Format
PLC value
Display
{DT602_5_S} DT602-DT606="ABCDEFGHIJ"
"ABCDE"
{DT602_5_.3S}
DT602-DT606="ABCDEFGHIJ"
"ABC "
{DT600_12_s} DT600=34
DT601=10
DT602-DT606="ABCDEFGHIJ"
"ABCDEFGHIJ "
{DT600_6_s} DT600=34
DT601=10
DT602-DT606="ABCDEFGHIJ"
"ABCDEF"
{DT602_5_c}
DT602-DT606="ABCDEFGHIJ"
"A "
{DT602_1_c} DT602-DT606="ABCDEFGHIJ"
"A"
f) Examples of displaying integers with a decimal point
With the latest version the '.precision' (range 1...9) format specification can be used