Accessories – Lincoln Electric IDEALARC SVM 122-A User Manual
Page 35

CONNECTING THE LN-8 OR LN-9 TO THE
IDEALARC DC-400 (14-PIN AMPHENOL)
1.
Disconnect main AC input power to the Idealarc
DC-400.
2.
Set the POWER toggle switch to the OFF (0) posi-
tion.
3.
Connect the electrode cable from the LN-8 or
LN-9 to the “+” terminal of the welder. Connect
the work cable to the “-” terminal of the welder.
Reverse this hookup for negative polarity. See
Figure C.10.
NOTE: Welding cable must be sized for the current
and duty cycle of the application.
4.
Connect the input cable (K595-XX) between the
14-pin amphenol on the DC-400 and the input
cable plug on the LN-8 or LN-9. See Figure C.10.
5.
Set the welder VOLTMETER switch to the desired
polarity, either DC (-) or DC (+).
6.
Set the MODE switch to a CV (constant voltage)
position.
7.
Adjust wire feed speed at the LN-8 or LN-9 and
set the welding voltage with the WIRE FEEDER
VOLTAGE CONTROL.
Place the OUTPUT CONTROL switch in the “Remote”
position and the OUTPUT TERMINALS switch in the
“Remote” position.
ACCESSORIES
C-12
C-12
LINCOLN
®
ELECTRIC
IDEALARC DC-400
FIGURE C.10 – IDEALARC DC-400/LN-8 OR LN-9 WITH K595-XX CABLE
TO LN8/LN9 INPUT
CABLE PLUG
K595-XX INPUT CABLE ASSEMBLY