Troubleshooting & repair, Retest after repair – Lincoln Electric IDEALARC SVM 122-A User Manual
Page 105

TROUBLESHOOTING & REPAIR
F-61
F-61
LINCOLN
®
ELECTRIC
IDEALARC DC-400
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
INPUT IDLE AMPS AND WATTS
Input volts/Phase/Hertz
Maximum Idle Amps
Maximum Idle KW
200/3/60
10.9
1.2
208/3/60
10.5
1.2
220/3/60
9.9
1.2
230/3/60
9.5
1.2
380/3/60
5.8
1.2
400/3/60
5.5
1.2
415/3/60
5.3
1.2
440/3/60
5.0
1.2
460/3/60
4.8
1.2
500/3/60
4.4
1.2
575/3/60
3.8
1.2
200/3/50
19.8
1.3
220/3/50
18.0
1.3
230/3/50
17.2
1.3
380/3/50
10.4
1.3
400/3/50
9.9
1.3
415/3/50
9.5
1.3
440/3/50
9.0
1.3
500/3/50
7.9
1.3
OPEN CIRCUIT VOLTAGES
Mode
Input Hertz
Open Circuit Volts
Constant Current
60
54/58
Constant Current
50
51/55
Constant Voltage
60
42.5/46.5
(FCAW/GMAW)
50
42.5/46.5
Constant Voltage
60
43.5/47.5
(SUB ARC)
50
43.5/47.5
Auxiliary Output (#31-#32)
60
114/124
Auxiliary Output (#31-#32)
50
109/119
Auxiliary Output (#41-#42)
60
43.8/47.5
Auxiliary Output (#41-#42)
50