Barcode control flag, Setup barcode data, Barcode control flag -41 – Lexmark 258x User Manual
Page 61: Setup barcode data -41, Bar code

Bar Code
2-41
Draft document
Barcode Control Flag
The control flag is made up of 8 bits as follows:
Setup Barcode Data
This command sets the barcode data on the current printing position.
Model
Dec
Hex
Vertical Pitch
all barcodes except
Post-Net
a
24 wire (259X)
12
0C
1/180 inch
9 wire (248X)
30
1E
1/72 inch
Model
Dec
Hex
long bar height
short bar height
Post-Net
b
24 wire (259X)
288
120
24/180 inch
8/180 inch
9 wire (248X)
270
10E
18/144 inch
6/144 inch
a. All the input data is rounded to the multiple value shown.
b. Barcode height is fixed to the values shown.
Table 2-21: Barcode Control Flags
Bit
Description
Decimal
Hexadecimal Effect
b1
Check Digit
0
00
No check code is generated by the printer.
The host computer should generate the
check code.
1
01
Check code is generated automatically by
the printer.
b2
Human Readable Character
0
00
Print On
1
01
Print Off
b3
EAN-13 (13th digit), UPC-A
(number system character) flag
character position
0
00
Center
1
01
Under
b4-b8
not used
Format
ESC
[
p
n1
n2
d1
d2
Decimal
27
91
112
n1
n2
d1
d2
Hexadecimal 1B
5B
70
n1
n2
d1
d2
Table 2-20: Barcode Length (Continued)
V1, V2 value