FOREWORD

These designs comply with ANSI Z21.10.3 as a Booster type

water heater.

Detailed installation diagrams are found in this manual. These

diagrams will serve to provide the installer with a reference for the

materials and methods of piping necessary. It is highly essential that

all water, gas piping and wiring be installed as shown on the diagrams.

Particular attention should be given to the installation of

thermometers at the locations indicated on the diagrams as these

are necessary for checking the proper functioning of the heater.

These heaters may be installed on combustible floors.

In addition to these instructions, the equipment shall be installed

in accordance with those installation regulations in force in the

local area where the installation is to be made. These shall be

carefully followed in all cases. Authorities having jurisdiction

should be consulted before installations are made.

The installation must conform to these instructions and the

local code authority having jurisdiction. In the absence of local

codes, the installation must comply with the latest editions of

the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the

National Electrical Code, NFPA 70, documents are available from

the National Fire Protection Association, 1 Batterymarch Park,

Quincy, MA 02269.

ROUGH-IN-DIMENSIONS

FIGURE 1

TABLE 1 - HEATER PERFORMANCE DATA

Input

Approx.

RECOVERY RATING CAPACITIES (GPH) AT TEMPERATURE RISE SHOWN

Rate

Tank Approx. F 20°F 30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F

Model

Btuh

Cap.

Eff. %

C 11°C 17°C 22°C 28°C 33°C 39°C 44°C 50°C 56°C 61°C 67°C 72°C 78°C

CGN150032 150,000 NAT

32 Gal

80

GPH 727 485 364 291 242 208 182 162 145 132

121

112 104

44 kW/Hr. NAT 121 Litres

LPH 2752 1836 1378 1102 916 787 689 613 549 500

458

424 394

CGL150032

150,000 LP

32 Gal

80

GPH 727 485 364 291 242 208 182 162 145 132

121

112 104

44 kW/Hr. LP 121 Litres

LPH 2752 1836 1378 1102 916 787 689 613 549 500

458

424 394

CGN200032 199,900 NAT

32 Gal

80

GPH 969 646 485 388 323 277 242 215 194 176

162

149 139

59 kW/Hr. NAT 121 Litres

LPH 3668 2445 1836 1469 1223 1049 916 814 734 666

613

564 526

CGL200032 182,000 LP

32 Gal

80

GPH 882 588 441 353 294 252 221 196 177 160

147

136 126

53 kW/Hr. LP 121 Litres

LPH 3339 2226 1669 1336 1113 954 837 742 670 606

557

515 477