beautypg.com

Performance data, Sdt/set installation & operation manual – Lochinvar SQUIRE SDT/SET065 - 119 User Manual

Page 23

background image

SDT/SET Installation & Operation Manual

Table 8D First Hour Rating - 180°F Boiler Loop Water (Universal Sizing. Upper Coil SDT Models)

First Hour Rating - 180°F Boiler Loop Water

(Universal Sizing - 45,000 - 295,000 Btu/hr / SDT065-SDT119)

Boiler Supply Water

180

180

180

Circulator Flow GPM

5

8

12

16

20

5

8

12

16

20

5

8

12

16

20

Domestic Outlet

115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140

45,000

117 92

117

91

122 97 122 97

138 113 138 113

60,000

146 112 146 112

151 117 151 117

168 134 168 134

75,000

174 133 174 133

180 138 180 138

197 154 197 154

95,000

205 154 213 160 213 160

210 159 218 165 218 165

236 182 236 182 236 182

115,000

205 154 235 175 254 189 254 189

210 159 240 180 254 190 254 190

275 210 275 210 275 210 275 210

140,000

205 154 235 175 260 193 286 211 295 218 210 159 240 180 260 195 286 213 306 227 292 222 324 244 324 244 324 244 324 244

165,000

205 154 235 175 260 193 286 211 295 218 210 159 240 180 260 195 286 213 306 227 292 222 341 257 373 279 373 279 373 279

195,000

235 175 260 193 286 211 295 218

240 180 260 195 286 213 306 227

341 257 385 288 413 308 431 320

225,000

260 193 286 211 295 218

260 195 286 213 306 227

385 288 413 308 475 351

260,000

295 218

306 227

475 351

295,000

475 351

MAX BTU INPUT

90256

106525

118352

131827

139966

90257

106525

118352

131827

139967

123218

148780

171607

185675

217372

Boiler H

eat

ing Capacit

y

Model SDT065 SDT080 SDT119

23

8

Performance Data

(continued)

Table 8C First Hour Rating - 180°F Boiler Loop Water (Knight and Wall Mount Boilers, Upper Coil SDT Models)

First Hour Rating - 180°F Boiler Loop Water

(Knight Boiler - SDT065 - SDT119)

Model SDT065 SDT080 SDT119

Boiler Supply Water

180

180

180

Circulator Flow

GPM

5

8

12

16

20

5

8

12

16

20

5

8

12

16

20

Domestic Outlet

115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140

45,000

117 92 117 92

122 97 122 97

138 113 138 113

72,000

169 129 169 129

174 134 174 134

191 150 191 150

94,000

205 154 211 159

210 159 216 164

234 181 234 181

135,000

235 176 255 190

240 181 260 195

314 238 314 237

190,000

255 190 281 208

260 195 286 213

385 288 413 308

260,000

255 190 281 208 301 222

260 195 286 213 306 227

385 288 413 308 475 351

373,000

301 222

306 227

475 351

467,000

301 222

306 227

475 351

MAX BTU INPUT

90256

106525

116697

130105

139966

90257

106525

116698

130105

139967

123218

148780

171607

185675

217372

WB050

K/WB081

K/WB106

K/WB151

K/WB211

KB286

KB400

KB501

Boiler H

eat

ing Capacit

y

Note: Testing conducted with 50°F inlet cold water

Note: Testing conducted with 50°F inlet cold water