SDT/SET Installation & Operation Manual

22

8

Performance Data

Table 8B SDT Backup Recovery Performance

How to Properly Size Your Indirect Water Heater

Use the First Hour Rating (FHR) to properly size your Indirect Water Heater. The FHR is the amount of hot water in gallons
the water heater can supply in the first hour of operation (starting with a tank full of hot water). The FHR is dependent on tank
capacity, source of heat, and the size of the burner.

The Indirect Water Heater and Boiler sizing charts can be found on pages 23 and 24. Locate your Indirect Water Heater and
Boiler along with your required First Hour Rating. This will also determine the flow needed between the Indirect Water Heater
and Boiler.

Table 8A SET Backup Recovery Performance

Model

Heat Exchanger

Volume
Gallons

Heated

Water

Volume
Gallons

Recovery

Back Up

Minutes

* First Draw

Gallons

Solar

65°F Rise

90°F Rise

115°F

140°F

SET065

2.2

28

78

108

34

26

SET080

2.2

35

89

123

44

31

SET119

3.2

44

120

166

55

42

Model

Heat Exchanger

Volume
Gallons

Heated

Water

Volume
Gallons

Recovery

Back Up

Minutes

Boiler

Output for

Recovery

BTU/HR

* First Draw

Gallons

Boiler

Solar

65°F Rise

90°F Rise

115°F

140°F

SDT065

1.9

2.2

32

8

13

128,000

42

30

SDT080

1.9

2.2

36

9

15

128,000

49

35

SDT119

2.6

3.2

53

10

17

217,000

65

50

*

Amount of water drawn from tank with no energy input

NOTICE

The charts utilize only the upper boiler

coil and the upper half of the tank.