Installation

2) Adjusting air volume to the height of ceiling

You can choose the RPM(or air volume) of indoor motor according to the height of ceiling to supply the com-
fortable atmosphere to consumers.

Procedure

1. Choose the selectable position in the table after measuring the height of ceiling.

2. In the case of changing the height as "high" or "low", open the rear cover of the wired remote-controller.

3. Move the slide switch to the set position.

4. Close the rear cover and check if it works nomally.

Slide switch for
ceiling height

1
2
3

1
2
3

1

2

3

Ceiling height

Mode of slide switch

Change of air volume

Remark

more than 3.3m(10.8ft)

High Ceiling

Increasing

2.7~3.3m(8.9~10.8ft)

Standard

-

less than 2.7m(8.9ft)

Low Ceiling

Decreasing

Maunfactured in stan-

dard mode

3) Group Control

• Be careful not to exchange the color of wires.
• The maximum length of connecting wire should be below 200m(656ft)(25

Ω) on connecting each units.

• Use a wire more than 0.5mm

2

CAUTION

It operates maximum 16 Units by only one Wired Remote Controller, and each Unit starts sequentially to prevent
overcurrent.

Wiring design

Operation unit

ZONE

1 2 3 4

Humidify

JET

AUTO

AUTO SWING

OPERATION

FAN SPEED

Program set

SUB FUNCTION

SET TEMP

Room Temp

HI
MED
LO

Heater
Defrost
Filter

Preheat

Out door

Time

Timer
On
Set no. Time

Off

01

03

05

07

09

11

13

15

17

19

21

23

Indoor Unit 1

Terminal(Local Supply)
Block

Terminal(Local Supply)
Block

Terminal(Local Supply)
Block

Main PCB

#1

Main PCB

#2

Main PCB

#16

Wired Remote Controller

Indoor Unit 2

Main PCB

Indoor Unit 16

Connector

RED(12V)

YL(SIGNAL)

BR(GND)

RED(12V)

YL(SIGNAL)

BR(GND)

YL(SIGNAL)

BR(GND)

Connecting Cable(Local Supply)

Connector

Connector

....

....

YL(SIGNAL)

BR(GND)

YL(SIGNAL)

BR(GND)

YL(SIGNAL)

BR(GND)

Remote

Controller

PCB

Single Control

Group Control 1

Group Control 2

S/W GR

• Using the supplied Wired Remote Controller, wire

them like above.

• Move S/W GR to "Group Control 1" position.
• Check the line color of the wire.