beautypg.com

Troubleshooting – Lincoln Electric INVERTEC IM958 User Manual

Page 34

background image

E-5

TROUBLESHOOTING

E-5

V310-T AC/DC TIG

The V310-T ACDC, when a fault condition is detected, dis-

plays on the graphics LCD an alarm notification composed

of:

ALARM ICON + ALARM CODE + ALARM TYPE ICON

Exx

When a fault condition is detected, the power source and the

cooler are switched in safety mode, it means the welding

operation are stopped. To recover from a fault condition, it is

necessary to remove the cause and exit the safety mode

depressing the exit key button on the UI.

ALARM ID CODES:

E01, E02, E03

E10

E11, E19

E14, E15, E18

E17

E20

E21

E22

E27

E28

E29

E38

E39,E40

E43

E44

E99

Temperature alarm

Boost/Inverter overcurrent

System configuration alarm

Program not valid alarm

Communication alarm (µP-DSP)-Type 1

Memory fault alarm

Data loss alarm

Communication alarm (µP-DSP)-Type 2

Memory_1 fault alarm

Memory_2 fault alarm

Output power alarm

Under voltage alarm

System power supply alarm

Coolant shortage – clogged pipe alarm

Coolant temperature alarm

General alarm