A-4

INSTALLATION

V310-T AC/DC TIG

A-4
INPUT PLUG INSTALLATION

POWER CORD CONNECTION

A 10 ft. power cord is provided and wired into the

machine. Follow the power cord connection instruc-

tions.

Single Phase Input

Connect green lead to ground per National Electrical

Code.

Connect black and red leads to power.

Wrap white lead with tape to provide 600V insulation.

Three Phase Input

Connect green lead to ground per National Electric

Code.

Connect black, red and white leads to power.

Failure to wire as instructed may cause personal

injury or damage to equipment. To be installed

or checked by an electrician or qualified person

only.

---------------------------------------------------------------------------

In all cases, the green or green/yellow grounding wire

must be connected to the grounding pin of the plug, usu-

ally identified by a green screw.

Attachment plugs must comply with the Standard for

Attachment Plugs and Receptacles, UL498.

The product is considered acceptable for use only when

an attachment plug as specified is properly attached to

the supply cord.

For use on engine drives, keep in mind the above input

draw restrictions and the following precaution.

ENGINE DRIVEN GENERATOR

The Invertec V310-T AC/DC TIG can be operated on

engine driven generators as long as the 230 volt auxil-

iary meets the following conditions:

• The AC waveform peak voltage is below 400 volts.

• The AC waveform frequency is between 45 and

65Hz.

The following Lincoln engine drives meet these condi-

tions when run in the high idle mode:

• Ranger 250, 305

• Vantage 300, 400, 500

Some engine drives do not meet these conditions

(e.g. Miller Bobcats, etc). Operation of the Invertec

V310-T AC/DC is not recommended on engine drives

not conforming to these conditions. Such drives may

deliver unacceptably high voltage levels to the

Invertec V310-T AC/DC power source.