beautypg.com

Operation – Lincoln Electric INVERTEC IM958 User Manual

Page 25

background image

B-10

OPERATION

B-10

V310-T AC/DC TIG

TABLE B.4 (Continued)

SET UP MENU PARAMETERS

Selection/

* Default Value

Display Off

Display in 7 Segment LED

Display*

Display Off*

Display in 7 Segment LED

Display

Display Off*

Display in 7 Segment LED

Display

Display Off*

Display in 7 Segment LED

Display

This function sets the initial start energy

limit. Set this number to a higher setting

than the factory default if needed to

improve starting of large diameter tungsten

electrodes.

0.5 to 1.0 manual start energy setting.

1.2 to 5.0 = max. Incrementing limit.

(See Note)

Note: The machine will try to start the arc at

a start power of 1. If the arc does not

establish it will incrementally increase

the start power and try to restrike up

to the set limit.

Parameter

Number

751

752

753

754

104

Description

Output Current Displayed

Output Voltage Displayed

Input Phase Displayed

Input Voltage Displayed

AC TIG Start Power (for AC TIG only)

Parameter

Symbol

OPTIONAL COOL-ARC 35 WATER

COOLER

The optional Cool-Arc 35 water cooler is designed to

operate in communication with the V310-T AC/DC.

Refer to the Cool-Arc 35 operator manual for installa-

tion instructions and a complete description of its

operation.

When the V310-T AC/DC is powered ON the Cool-Arc

35 will automatically power ON as well. The Cool-Arc

35 monitors pressure and temperature and will adjust

the pump speed accordingly to cool the torch. If a

blockage of coolant or loss of coolant is sensed both

the Cool-Arc 35 and V310-T AC/DC will display an

error and turn off the V310-T AC/DCʼs output.

IMPORTANT: If the Cool-Arc 35 water cooler is

connected to the V310-T AC/DC and an air cooled

torch is connected instead of a water cooled torch

the Cool-Arc 35 will sense a coolant blockage

resulting in a cooler error.

In this case the cooler can be turned to the “off mode”

by depressing and holding the push button on the

cooler until the coolerʼs display reads “oo”. To turn

the cooler back on you can depress and hold the

Cool-Arc 35 push button until the coolerʼs digital dis-

play reads coolant temperature in degrees Celsius.

Turning the V310-T AC/DC off and on again will auto-

matically turn the water cooler back on as well.