Lenovo THINKCENTRE 6396 User Manual
Page 77
Diagnostic
Error
Code
FRU/Action
175-198-XXX
Thermal
Sensor(s)
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test.
See
3.
Go
to
175-199-XXX
Thermal
Sensor(s)
test
failed,
cause
unknown
1.
See
2.
Flash
the
system
and
re-test.
See
3.
Replace
component
under
function
test
175-250-XXX
175-251-XXX
Thermal
Sensor(s)
limit
error
1.
Check
fans
2.
Check
AC/DC
power
adapter
voltages
3.
Microprocessor
4.
System
board
185-000-XXX
Asset
Security
Test
Passed
No
action
185-XXX-XXX
Asset
Security
failure
1.
Flash
system
2.
System
board
185-278-XXX
Asset
Security
Chassis
Intrusion
1.
Assure
Asset
Security
Enabled
2.
C2
Cover
Switch
3.
System
board
201-000-XXX
System
Memory
Test
Passed
No
action
201-XXX-XXX
System
Memory
error
1.
Replace
the
memory
module
called
out
by
the
test
2.
System
board
202-000-XXX
System
Cache
Test
Passed
No
action
202-XXX-XXX
System
Cache
error
1.
Cache,
if
removable
2.
System
board
3.
Microprocessor
206-000-XXX
Diskette
Drive
Test
Passed
No
action
206-XXX-XXX
Diskette
Drive
error
1.
Diskette
Drive
Cable
2.
Check
AC/DC
power
adapter
voltages
3.
Diskette
drive
4.
System
board
215-000-XXX
CD-ROM
Drive
Test
Passed
No
action
Chapter
7.
Symptom-to-FRU
Index
71