Lenovo THINKCENTRE 6396 User Manual
Page 62
Diagnostic
Error
Code
FRU/Action
001-024-XXX
System
Addressing
test
failure
System
board
001-025-XXX
System
Checksum
Value
error
1.
Flash
the
system.
See
2.
System
board
001-026-XXX
System
FLASH
data
error
1.
Flash
the
system.
See
2.
System
board
001-027-XXX
System
Configuration/Setup
error
1.
Run
Setup
2.
Flash
the
system.
See
3.
System
board
001-032-XXX
System
Device
Controller
failure
System
board
001-034-XXX
System
Device
Buffer
Allocation
failure
1.
Reboot
the
system
2.
Flash
the
system.
See
3.
Run
memory
test
4.
System
board
001-035-XXX
System
Device
Reset
condition
detected
System
board
001-036-XXX
System
Register
error
System
board
001-038-XXX
System
Extension
failure
1.
Adapter
card
2.
System
board
001-039-XXX
System
DMI
data
structure
error
1.
Flash
the
system.
See
2.
System
board
001-040-XXX
System
IRQ
failure
1.
Power-off/on
system
and
re-test
2.
System
board
001-041-XXX
System
DMA
failure
1.
Power-off/on
system
and
re-test
2.
System
board
001-195-XXX
System
Test
aborted
by
user
Information
only
Re-start
the
test,
if
necessary
001-196-XXX
System
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
56
Hardware
Maintenance
Manual