Diagnostic
Error
Code
FRU/Action
001-197-XXX
System
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled.
See
2.
Re-run
test
3.
Replace
the
component
that
is
called
out
in
warning
statement
4.
Replace
the
component
under
test
001-198-XXX
System
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled.
See
2.
Flash
the
system
and
retest.
See
3.
Go
to
001-199-XXX
System
test
failed,
cause
unknown
1.
Go
to
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
001-250-XXX
System
ECC
error
System
board
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System
DMA
error
System
board
001-260-XXX
001-264-XXX
System
IRQ
error
System
board
001-268-XXX
System
IRQ1
failure
1.
Device
on
IRQ1
2.
System
board
001-269-XXX
System
IRQ2
failure
1.
Device
on
IRQ2
2.
System
board
001-270-XXX
System
IRQ3
failure
1.
Device
on
IRQ3
2.
System
board
001-271-XXX
System
IRQ4
failure
1.
Device
on
IRQ4
2.
System
board
001-272-XXX
System
IRQ5
failure
1.
Device
on
IRQ5
2.
System
board
001-273-XXX
System
IRQ6
(diskette
drive)
failure
1.
Diskette
Cable
2.
Diskette
drive
3.
System
board
001-274-XXX
System
IRQ7
failure
1.
Device
on
IRQ7
2.
System
board
Chapter
7.
Symptom-to-FRU
Index