beautypg.com

Lennox Hearth MPD35ST-NM User Manual

Page 17

background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

17

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Inspecting/Cleaning Burner, Logs

and Controls

Qualifi ed Service Technician

Inspect valve and ensure it is properly operating. Check piping

for leaks. Vacuum the control compartment, fi replace logs and

burner area.

Check Flame Patterns and Flame

Height

Qualifi ed Service Technician

Refer to Figure 13 on Page 9 and verify the fl ame pattern and

height displayed by the appliance conforms to the picture. Flames

must not impinge on the logs. Ensure fl ames are steady (not

lifting or fl oating).

Inspecting/Cleaning Pilot and Burner

Qualifi ed Service Technician

Refer to Figure 15 and Figure 16 on Page 10. Remove any

surface build-up on pilot and burner assembly. Wipe the pilot

nozzles, igniter/fl ame rod and hood. Ensure the pilot fl ame

engulfs the fl ame sensor as shown.

Checking Vent System

Qualifi ed Service Technician

Inspect the vent system at the top and at the base (within the

fi rebox) for signs of blockage or obstruction. Look for any signs

of dislocation or deterioration of the vent components. Note:

Excessive condensation can cause corrosion of caps, pipe &

fi ttings (excessive condensation can be caused by long lateral

runs, too many elbows and/or exterior portions of the system

being exposed to cold weather). Also inspect wall straps or

plumbers's tape to ensure it is secure and in place.

Appliance Checkout

Qualifi ed Service Technician

Perform the appropriate appliance checkout procedure detailed

in this manual.

Replacing Rockwool Ember Materials

Homeowner/Qualifi ed Service

Technician

Remove old ember materials (rockwool) and vacuum the ember
placement area. Place new embers as described in Step 6 on
Page 8.

Periodically (After the Burning Season)

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Cleaning Firebox Interior

Homeowner

Carefully remove logs, rockwool, volcanic stone and vermiculite.

Vacuum out interior of the fi rebox. Clean fi rebox walls and log

grate. Replace logs, Rockwool and volcanic stone as detailed

in this manual.

Check Flame Patterns and Flame

Height

Homeowner

Refer to Figure 13 on Page 9 and verify the fl ame pattern and

height displayed by the appliance conforms to the picture. Flames

must not impinge on the logs.

Checking Vent System

Homeowner

Inspect the vent system at the top and at the base (within the

fi rebox) for signs of blockage or obstruction. Look for any signs

of dislocation of the vent components.

Cleaning Front Glass Enclosure Panel

Homeowner

Clean as necessary following the directions provided in this

manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS

WHILE HOT.

Annually (Before the onset of the Burning Season)

MAINTENANCE SCHEDULE

This manual is related to the following products: