beautypg.com

Installation, Technical specifications – dc-1000 – Lincoln Electric IDEALARC IM420-D User Manual

Page 8

background image

A-1

INSTALLATION

IDEALARC® DC-1000

A-1

60% Duty Cycle

215/108

86

215/124/108

124/94

113

TECHNICAL SPECIFICATIONS – DC-1000

Volts at Rated Amperes

44

44

44

Auxiliary Power

See the OPERATION section

for Auxiliary Power

information by model

Amps

1000

1140

1250

Maximum Open Circuit Voltage

75V for 60 HZ models

72V for 50/60 HZ models

Duty Cycle

100% Duty Cycle

60% Duty Cycle

50% Duty Cycle

Output Range

150A/16V-1300A/46V

INPUT - THREE PHASE ONLY

OUTPUT

1Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.

RECOMMENDED INPUT WIRE AND FUSE SIZES

Standard

Voltage

230/460/60

575/60

220/380/440/50/60

380/500/50/60

415/50/60

100% Duty Cycle

193/96.5

77.2

193/112/96.5

112/85

102

50% Duty Cycle

230/115

92

230/133/115

133/101

121

Input Current at Rated Output

RATED OUTPUT

INPUT

VOLTAGE /

FREQUENCY

230

460

575

220

380

415

440

500

TYPE 75°C

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

1

300 Amp

150 Amp

125 Amp

300 Amp

175 Amp

150 Amp

150 Amp

125 Amp

TYPE 75°C

GROUND WIRE

IN CONDUIT

AWG(IEC-MM

2

) SIZES

4 (21)

6 (14)

6 (14)

4 (21)

6 (14)

6 (14)

6 (14)

6 (14)

TYPE 75°C

COPPER WIRE

IN CONDUIT

AWG(IEC-MM

2

) SIZES

30°C (86°F) Ambient

000 (85)

3 (27)

4 (21)

000 (85)

2 (34)

2 (34)

3 (27)

4 (21)

INPUT AMPERE

RATING ON

NAMEPLATE

193

96.5

77.2

193

112

102

96.5

85

HERTZ

60

60

60

50/60

50/60

50/60

50/60

50/60

PHYSICAL DIMENSIONS

HEIGHT

30.75 in

781 mm

WIDTH

22.25 in

567 mm

DEPTH

39.0 in

991 mm

WEIGHT

821 lbs.

372 kg.