Lenovo Z61e User Manual
Page 54
Symptom
or
error
FRU
or
action,
in
sequence
1810
Hard
disk
partition
layout
error.
1.
If
the
Access
Predesktop
Area
has
been
previously
disabled,
then
go
to
the
BIOS
Setup
Utility
by
pressing
F1
to
open
the
BIOS
Setup
Utility.
Select
Security
-->
Predesktop
Area
-->
Access
Predesktop
Area.
Set
this
item
to
Disabled.
Save
and
exit.
2.
If
the
Access
Predesktop
Area
has
not
been
previously
disabled,
press
Enter
to
load
Access
Predesktop
Area.
Then
run
RECOVER
TO
FACTORY
CONTENTS
in
Access
Predesktop
Area.
3.
If
item
2
failed,
press
F3
in
the
Welcome
screen
in
RECOVER
TO
FACTORY
CONTENTS
.
Run
FDISK,
and
then
delete
all
partitions.
Run
RECOVER
TO
FACTORY
CONTENTS
in
Access
Predesktop
Area
again.
4.
If
item
3
failed,
select
CD-ROM
boot
in
Startup
in
Access
Predesktop
Area.
Boot
from
the
Recovery
CD
and
perform
full
recovery
from
it.
5.
If
item
4
failed,
replace
the
hard
disk
drive.
1820
More
than
one
external
fingerprint
reader
is
attached.
Power
off
and
remove
all
but
the
reader
that
you
set
up
within
your
main
operating
system.
Remove
all
but
the
reader
that
you
set
up
for
the
authentication.
2000
Hard
Drive
Active
Protection
sensor
diagnostics
failed.
Press
to
continue.
Press
to
enter
SETUP
1.
Undock
docking
station
or
port
replicator
if
it
is
attached
to
the
ThinkPad
computer,
and
place
the
computer
on
a
horizontal
surface.
Do
not
apply
any
physical
shock
to
the
computer.
2.
Run
Diagnostics
-->
ThinkPad
Devices
-->
HDD
Active
Protection
Test
.
2010
Warning:
Your
internal
hard
disk
drive
(HDD)
may
not
function
correctly
on
this
system.
Ensure
that
your
HDD
is
supported
on
this
system
and
that
the
latest
HDD
firmware
is
installed.
Inform
the
following
information
to
the
customer:
If
in
the
primary
bay
the
customer
is
using
a
non-IBM
or
non-Lenovo
hard
disk
drive
(HDD),
or
an
old
generation
IBM
HDD
which
is
not
supported
by
this
system,
with
the
risk
in
mind,
the
customer
can
still
use
it
by
pressing
ESC.
If
in
the
primary
drive
bay
the
customer
is
using
a
supported
IBM/Lenovo
HDD
with
an
old
firmware,
the
customer
needs
to
update
its
firmware
to
the
latest.
The
latest
version
is
available
at
2100
Initialization
error
on
HDD0
(Main
hard
disk
drive)
1.
Reseat
the
hard
disk
drive.
2.
Main
hard
disk
drive.
3.
System
board.
2102
Initialization
error
on
HDD1
(Ultrabay
hard
disk
drive)
1.
Reseat
the
hard
disk
drive.
2.
Ultrabay
hard
disk
drive.
3.
System
board.
Symptom-to-FRU
index
48
MT
0660,
0672,
0673,
0674,
0675,
9450,
9451,
9452,
and
9453