Liebert 1500 User Manual
Liebert Tools
Table of contents
Document Outline
- 1.0 About This Document
- 2.0 Introduction
- 3.0 Specifications
- 3.1 Framework
- 3.2 Conventional Controller
- 3.3 Distribution Panels
- 3.3.1 Fuse Panels
- Mechanical specifications of the fuse panels
- Table 6 Mechanical specifications of the fuse panels
- Figure 5 Front view of the 20 QFF 0-5 A fuse panels
- Table 7 Fuse sizes available for the (20) QFF 0-5 A fuse panels
- Figure 6 Front view of the (16) QFF 0-5 A & (12) ABS 5-30 A fuse panels
- Table 8 Fuse sizes available for the (16) QFF 0-5 A & (12) ABS 5-30 A fuse panels
- Figure 7 Front view of the (16) QFF 0-5 A & (6) TPN 5-30 A fuse panels
- Table 9 Fuse sizes available for the (16) QFF 0-5 A & (6) TPN 5-30 A fuse panels
- Figure 8 Front view of the (8) TPN 5-30 A fuse panels
- Table 10 Fuse sizes available for the (8) TPN 5-30 A fuse panels
- Figure 9 Front view of the (4) RS100P 70-100 A fuse panels
- Table 11 Fuse sizes available for the (4) RS100P 70-100 A fuse panels
- Figure 10 Front view of the (4) CRS200P 150-200A/(4) CRS200P 150200A (w/load shunts) fuse pa...
- Table 12 Fuse sizes available for the (4) CRS200P 150-200 A/(4) CRS200P 150200A (w/load shunt...
- Figure 11 Front view of the (4) TPL 225-600 A fuse panels
- Table 13 Fuse sizes available for the (4) TPL 225-600 A fuse panels
- Figure 12 Front view of the (18) TPS 1-70 A fuse panel
- Table 14 Fuse sizes available for the (18) TPS 1-70 A fuse panel
- Electrical specifications of the fuse panels
- Table 15 Electrical specifications of the fuse panels
- 3.3.2 Circuit Breaker Panels
- Mechanical specifications of the circuit breaker panels
- Table 16 Mechanical specifications of the circuit breaker panels
- Figure 13 Front view of the (24) Plug-In 1-100 A circuit breaker panel
- Table 17 Plug-in circuit breakers available for the (24) Plug-In 1-100 A circuit breaker panel
- Figure 14 Front view of the (4) 70-250 A circuit breaker panel
- Table 18 Circuit breaker sizes available for the (4) 70-250 A circuit breaker panel
- Figure 15 Front view of the (2) 400 A circuit breaker panel
- Table 19 Circuit breaker kits available for the (2) 400 A circuit breaker panel
- Figure 16 Front view of the (1) 600-700 A circuit breaker panel
- Table 20 Circuit breaker kits available for the (1) 600-700 A circuit breaker panel
- Electrical specifications of the circuit breaker panels
- Table 21 Electrical specifications of the circuit breaker panels
- 3.3.1 Fuse Panels
- 3.4 Externally Mounted Battery Return Busbar
- 3.5 Terminating Assemblies (Optional)
- 3.6 MPS300 and MPA100 Power Shelves
- 3.7 Rectifiers
- 3.8 Helios Monitor 3000/48 (Optional)
- 3.9 600A and 1200A Battery Disconnect Unit (Optional)
- 3.10 AC Junction Box
- 3.11 Overall Power System Specifications
- 4.0 Operation
- 4.1 General
- 4.2 Conventional Controller
- 4.2.1 Front Panel
- Figure 26 Front view of the Conventional Controller
- Visual indicators
- Table 32 Visual indicators
- Table 33 Transmitted alarms
- Potentiometers
- Table 34 Potentiometers
- Switches
- Table 35 Switches
- DIP switches
- Table 36 DIP switch modules
- Figure 27 Shunt range selection settings
- Figure 28 Equalize voltage and duration settings
- Fuses
- Table 37 Fuse
- Test points
- Table 38 Test points
- 4.2.2 Rear Panel
- 4.2.1 Front Panel
- 4.3 MPS300 and MPA100 Power Shelves
- 4.4 Rectifiers
- 4.5 AC Junction Box
- 4.6 Distribution Panels
- 4.7 Terminating Assemblies (Optional)
- 4.8 Helios Monitor 3000/48 (Optional)
- 4.9 600A and 1200 Battery Disconnect Units (Optional)
- 5.0 Maintenance
- 5.1 General
- 5.2 Troubleshooting
- 5.3 Addition / Replacement Procedures
- 5.3.1 Addition or Replacement of a Rectifier
- Adding a Helios Rectifier 100/48
- Adding a Helios Rectifier 200I/48 or 200E/48
- Figure 32 AC connections in a Helios Rectifier 200E/48
- Figure 33 AC connections in the female receptacle for a Helios Rectifier 200I/48 or a Helios Rect...
- Figure 34 AC connections inside the junction box (top fed shown) for a Helios Rectifier 200E/48
- Figure 35 AC cable routing for the Helios Rectifiers 200E/48 in a top fed system
- Figure 36 AC cable routing for the Helios Rectifiers 200E/48 in a bottom fed system
- 5.3.2 Replacing a Rectifier
- 5.3.3 Adding or Replacing a Battery String
- 5.3.4 Replacement of a Distribution Fuse Block or Circuit Breaker
- 5.3.5 Replacing a Cabinet Alarm Lamp
- 5.3.1 Addition or Replacement of a Rectifier
- 6.0 Reference Documents
- 7.0 List of Terms