beautypg.com

Linksys SRW2016 User Manual

Page 52

background image

42

Chapter 5: Using the Web-based Utility for Configuration
Security Tab - 802.1x Port Conf. (Configuration)

WebView Switches

To modify the settings for an 802.1x port, click the port’s Edit icon. On the new screen that appears, you can
modify the port settings.

Port. This is the port name.

Admin Port Control. Select forceAuthorized if you want traffic to be forwarded. Select forceUnauthorized if
you want traffic to be discarded. Select Auto if you want the controlled port state set by the authentication
method.

Enable Periodic Reauthentication. Check this box if you want reauthentication to proceed automatically

Reauthentication Period. Enter the number of seconds that the Switch waits before initiating the
reauthentication process.

Quiet Period. Enter the number of seconds the Switch remains in the quiet state after an authentication
exchange has failed.

Resending EAP. Enter the number of seconds the Switch waits for a response to an EAP request/identity frame,
before resending the request.

Max EAP Requests. Enter the total number of EAP requests sent. If a response is not received in time, the
authentication process is restarted.

Supplicant Timeout. Enter the number of seconds that the Switch waits before EAP requests are resent to the
client.

Server Timeout. Enter the number of seconds that the Switch waits before it resends a request to the RADIUS
server.

Click the Submit button to save your changes.

Figure 5-35: 802.1x Port Configuration - Change Settings