5-16
Lucent Technologies Inc.
USS-720
Instant USB
Preliminary Data Sheet, Rev. 5
USB-to-
IEEE
1284 Bridge
September 1999
13
IEEE 1284 Port
(continued)
Data Register
Status Register
Table 21. Data Register
Data Register
Address: 0
Bit
7
6
5
4
3
2
1
0
Symbol
D7
D6
D5
D4
D3
D2
D1
D0
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Default
0
0
0
0
0
0
0
0
Bit
Symbol
Bit Description
7—0
D7—D0
Data. This register is equivalent to and operates in the same manner as the Data
Register in a standard host-side parallel port controller chip. The register is writable
when Auto Mode is 0 and the Mode field in the Extended Control Register is set to
000 or 001. It is always readable. The read value will be the value of the data latched
into the register unless the Mode field is set to 001 and the Direction bit in the Control
Register is set to 1 (Input Mode). In this case, the read value will be the value present
on the parallel port data lines.
Table 22. Status Register
Status Register
Address: 1
Bit
7
6
5
4
3
2
1
0
Symbol
nBusy
nAck
PError
Select
nFault
—
PLH
Timeout
Access
Read
Read
Read
Read
Read
Read
Read
Read
Default
X
X
X
X
X
X
X
0
Bit
Symbol
Bit Description
7
nBusy
Inverted Busy. An inverted version of the parallel port Busy signal.
6
nAck
Parallel Port nAck Signal.
5
PError
Parallel Port PError Signal.
4
Select
Parallel Port Select Signal.
3
nFault
Parallel Port nFault Signal.
2
—
Reserved.
1
PLH
Peripheral Logic High. The parallel port PLH signal.
0
Timeout
EPP Time-Out. This bit indicates that a time-out has occurred during an EPP read or
write. If the peripheral fails to respond to an EPP read or write for longer than 10
µ
s,
this bit will be set and an interrupt will be returned if interrupts are enabled. This bit is
cleared by a read.