Configuration descriptor, Table 5 . configuration descriptor, Usb port – Lucent Technologies USS-720 User Manual
Page 33: Instant usb, Ieee

Preliminary Data Sheet, Rev. 5
USS-720
Instant USB
September 1999
USB-to-
IEEE
1284 Bridge
Lucent Technologies Inc.
5-7
13
USB Port
(continued)
Configuration Descriptor
The USS-720 has one default configuration descriptor. This descriptor has one interface, which has three alternate
settings. The three alternate settings and the endpoints that they support are shown in Table 4.
Table 4. Alternate Settings and Supported Endpoints
Endpoint
Interface
Alternate Setting 0
Alternate Setting 1
Alternate Setting 2
Control Pipe
Endpoint Number 0
8 bytes
Endpoint Number 0
8 bytes
Endpoint Number 0
8 bytes
Bulk Out Pipe
Endpoint Number 1
64 bytes
Endpoint Number 1
64 bytes
Endpoint Number 1
64 bytes
Bulk In Pipe
—
Endpoint Number 2
64 bytes
Endpoint Number 2
64 bytes
Interrupt Pipe
—
—
Endpoint Number 3
4 bytes
Table 5. Configuration Descriptor
Offset
Field
Size
Value
Description
0
bLength
Byte
0x09
Size of this descriptor in bytes.
1
bDescriptorType
Byte
0x02
Configuration descriptor type.
2
bTotalLength
Word 0x004E Number of bytes in this configuration. This includes the configura-
tion descriptor plus all of the interface and endpoint descriptors.
4
bNumInterfaces
Byte
0x01
The USS-720 has one interface.
5
bConfigurationValue Byte
0x01
Value to use as an argument to Set Configuration to select this con-
figuration.
6
iConfiguration
Byte
0x00
Index of string descriptor describing this configuration.
7
bmAttributes
Byte
0x80
Configuration characteristics:
Bit
Description
USS-720
7
Bus-powered.
Set.
6
Self-powered.
Cleared.
5
Remote wakeup.
Cleared.
4—0
Reserved, set to 0.
Cleared.
8
MaxPower
Byte
0x31
Maximum power consumption of this configuration. Units are