Interface 0, alternate setting 1 (i0:a1), Table 8 . interface descriptor, i0:a1, Table 9 . bulk out endpoint descriptor, i0:a1:e1 – Lucent Technologies USS-720 User Manual
Page 35: Table 10 . bulk in endpoint descriptor, i0:a1:e2, Usb port, Instant usb, Ieee

Preliminary Data Sheet, Rev. 5
USS-720
Instant USB
September 1999
USB-to-
IEEE
1284 Bridge
Lucent Technologies Inc.
5-9
13
USB Port
(continued)
Interface 0, Alternate Setting 1 (I0:A1)
Table 8. Interface Descriptor, I0:A1
Offset
Field
Size
Value
Description
0
bLength
Byte
0x09
Size of this descriptor in bytes.
1
bDescriptorType
Byte
0x04
Interface descriptor type.
2
bInterfaceNumber
Byte
0x00
Zero-based value identifying the number of this interface.
3
bAlternateSetting
Byte
0x01
Value used to select this alternate interface.
4
bNumEndpoints
Byte
0x02
Number of endpoints used by this descriptor.
5
bInterfaceClass
Byte
0x07
Printer class.
6
iInterfaceSubClass
Byte
0x01
Printer subclass.
7
bInterfaceProtocol
Byte
0x02
Bidirectional interface.
8
iInterface
Byte
0x00
Index to string describing this interface.
Table 9. Bulk Out Endpoint Descriptor, I0:A1:E1
Offset
Field
Size
Value
Description
0
bLength
Byte
0x07
Size of this descriptor in bytes.
1
bDescriptorType
Byte
0x05
Endpoint descriptor type.
2
bEndpointAddress
Byte
0x01
This is an Out endpoint, endpoint number 1.
3
bmAttributes
Byte
0x02
This is a Bulk endpoint.
4
wMaxPacketSize
Word 0x0040 Maximum data transfer size.
6
bInterval
Byte
0x00
Does not apply to Bulk endpoints.
Table 10. Bulk In Endpoint Descriptor, I0:A1:E2
Offset
Field
Size
Value
Description
0
bLength
Byte
0x07
Size of this descriptor in bytes.
1
bDescriptorType
Byte
0x05
Endpoint descriptor type.
2
bEndpointAddress
Byte
0x82
This is an In endpoint, endpoint number 2.
3
bmAttributes
Byte
0x02
This is a Bulk endpoint.
4
wMaxPacketSize
Word 0x0040 Maximum data transfer size.
6
bInterval
Byte
0x00
Does not apply to Bulk endpoints.