NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

c

learances

To

c

omBusTiBles

WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN

THE HEATER AND THE SURFACE OF ANY COMBUSTIBLE CON-
STRUCTION IS NOT LESS THAN SHOWN.

Floor Protection

USA - The floor in front and under the heater must be pro-

tected with a minimum of 3/8” thick noncombustible material.

The covering must extend 16” in front of the door opening

of the heater and 8” to either side of the door opening and

5-1/2” to the rear or to the wall, whichever is smaller. In all

installations a 16” minimum hearth extension (in front of

the stove) is required as measured from the door opening

of the unit.

Canada - The floor in front and under the heater must be

protected with a minimum of 3/8” thick noncombustible

material. The covering must extend 457 mm in front of the

door opening of the heater and 200mm to either side of the

stove body and 200 mm to the rear or to the wall, whichever

is smaller. In all installations a 457mm minimum hearth

extension (in front of the stove) is required as measured

from the door opening of the unit.

Reduced Clearances

Clearances to combustible surfaces can be reduced with the

use of listed double wall connector pipe. See the clearances

with double wall pipe on the following page.

The Canyon™ ST310 may be installed using 6” chimney

in vertical installations utilizing a 6” to 8” reducer (part #

71134) at the flue collar. We recommend 6” chimney be

used in vertcal installations.

Alcove Clearances:

In alcove installations, only 6” or 8” double wall connector

pipe must

be used (single wall or single wall pipe with shield

is not allowed). Minimum alcove width between combus-

tible materials is 56-1/2”. Maximum alcove depth is 48”.

Minimum alcove height is 72”.

m

oBile

h

ome

i

nsTallaTions

All mobile home installations require an outside air kit

(Part # 71111 or 71112). The stove must be bolted to the

floor and grounded to the chassis of the mobile home.

WARNING: DO NOT INSTALL IN SLEEPING ROOM OF A

MOBILE HOME.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MO-

BILE HOME FLOOR, WALL, AND CEILING/ROOF MUST

BE MAINTAINED.

Approved Chimney* - Your stove is approved for use with

double wall connector pipe from Security™ Chimneys.

THIS APPLIANCE IS NOT APPROVED FOR USE WITH

SINGLE WALL PIPE. USE DOUBLE WALL CONNECTOR

PIPE ONLY.

Clearances to connector pipe shall be measured from the

flue collar of the stove.

Chimney & Connector

May only be installed using listed 6" or 8” double wall con-

nector pipe with listed factory-built chimney suitable for use

with solid fuels or masonry chimney. Horizontal connections

not tested, refer to local building codes for installation. May

be installed with 6” connector pipe and chimney using an 8”

to 6” reducer. See installation instructions for details.

Residential chimney systems must be from the same brands

of double wall pipe as listed for mobile homes.

Connector pipe and chimney must be of the same brand.

Components Required For Installation

Legs AND bottom heat shield or pedestal.

If optional blower is NOT used, rear heat shield block off

plate must be installed.

* Other approved chimney brands are Projet, Jakes Evans/GSW, Dura-vent,
Metal Fab, Ameri-Tec, Metalbestos and Industrial Chimney (ICC).