System Specifications
54-0166
71
Appendix A
System Specifications
Physical Characteristics
Antenna Unit
27.4" (70 cm) h x 26.2" (67 cm) d;
55 lbs (25 kg)
Operating temperature
–13° to +130° F (–25° to +55° C)
Storage temperature
–40° to +185° F (–40° to +85° C)
Input Power
Input
11–16 VDC @ 3.5 amps nominal
(4.5 amps peak)
Antenna System Performance
Minimum EIRP
47 dBW
Elevation range
10° - 80°
Azimuth range
720°
Pitch/roll range
±15°
Pitch/roll rate
30°/second
Turn rate
45°/second
Yaw
±90° in 10 seconds
Tracking rate
30° per second
Position repeatability
0.1°
Surge/sway/heave
±0.2 G
Shock
20 G, 11 msec
Vibration
0.9 G rms over 5-33 Hz
Table A-1
TracVision 6 Antenna
Physical Specifications
Table A-2
TracVision 6 Power Specifications
Table A-3
TracVision 6 Performance
Specifications