WTC 600 LP / MP
MAINTENANCE
Service Handbook 08.2004
4.5.4
Malfunctions – Media and Activated Carbon Filter, Fine Filter and Flocculation
Indication
Malfunction
Cause
Corrective Action
Chap./Fig.
More than one
Backwashing is
Load of debris
Install suitable preliminary 3.4.2.4
backwashing
initiated too often
too high
treatment; consultation
Tab. 24
per day
through sales
(diagnosis
controller)
Backwashing no
Pump defective
Replace pump or
sufficient
repair
Intake side of
Clean
pump clogged
Intake side of
Shorter line set-up;
pump too long
notify sales
Sand
Heavily soiled
Notify sales
conglutinated
water
Differential
Filtrate of the sand
Small particles
Install preliminary
4.1
pressure of
filter turbid
come through
treatment
fine filter quickly
exceeds 1 bar
Filtrate of the
Small particles
Check sand filter;
4.1
activated carbon
come through
install preliminary
filter turbid
treatment as required
Filter material
No backwashing Carry out backwashing;
3.4.2.1
conglutinated
carried out for too if without success,
long
replace sand
Too much
Reduce metering amount
flocculation agent of flocculation agent;
added
carry out backwashing
Indication of the
Power supply
Notify electrician
controller
disconnected
remains dark
Control wheel
Control switch or Replace controller
does not stand
switching
still
mechanism
defective
No changes of
Backwashing is
Controller
Change
3.4.2.4
the “back-
not initiated
incorrectly
programming
washing”
programmed
counter
Tabelle 31