MAINTENANCE
WTC 600 LP / MP
Service Handbook 08.2004
4.5
Malfunction, Cause and Corrective Action
4.5.1
Metering Station LED and Indicator LEDs at the Switch Cabinet
Indication
Malfunction
Cause
Corrective Action
Chap./
Fig.
Red fault LED
Pump in metering
Metering
Refill, check float switch
2.3.1.5,
lights
station blocked
container empty
3.2,3.3.2.4
Sensor signal
Check sensors,
2.3.1.5,
missing
check bridges in
ETL, 3.3.2
switch cabinet,
check sensor
wiring
Red
Backwashing of
Not necessary, as
2.3.1.5
regeneration
the sand filter or
the equipment
LED lights
activated carbon automatically
filter active
switches on again
Red tank full
Float switch in the
Drinking water
Not necessary, as
2.3.1.5,
LED lights
drinking water tank tank full
the equipment
3.3.2.4
has switched
automatically
switches on again;
Switch defective
Check switch, replace if
necessary
Table 27
Malfunction indications at the switch cabinet and their causes
Indication
Malfunction
Cause
Corrective Action
Chap./
Fig.
Green LED at
LED does not
No power supply Have fuse Q2
metering station flash when
checked from
pump does not
high-pressure
electrician
flash
pump runs
Operating mode
Set operating mode switch (1/10)
contact
to manual
Electrical defect
Replace pump
ETL
Red LED at
Pump blocked
Metering
Refill, check float switch
3.2,
metering
container empty
3.3.2.4
station pump
lights red
Cable that
Have cable checked
3.3.2.3
indicates empty
is broken
Auxiliary
Have auxiliary contactor
ETL, SLP
contactor in
replaced by electrician
switch cabinet
defective
Table 28
Metering station and metering pump LED