beautypg.com

F.3 operational commands – KVH Industries LF User Manual

Page 66

background image

Azimuth CCW Step

Function:

commands a 0.1 deg CCW manual step in azimuth
angle

Command:

4

Argument:

none

Response:

echoes the command

Elevation UP Step

Function:

commands a 0.1 deg UP manual step in elevation
angle

Command:

8

Argument:

none

Response:

echoes the command

Elevation DOWN Step

Function:

commands a 0.1 deg DOWN manual step in elevation
angle

Command:

2

Argument:

none

Response:

echoes the command

F.3

Operational Commands

Idle Mode

Function:

halts active tracking and conical scan, then enters
idle mode

Command:

HALT

Argument:

none

Response:

echoes the command

Current Cable Wrap Angle

Function:

sets or reports current cable wrap angle, defined as
0

º

(CCW limit) to 700

º

(CW limit); the value is

expressed as 0000-7000 with an implied decimal

Command:

WRAPANGLE,xxxx

Argument:

the desired cable wrap angle setting

Response:

Wrap Angle = xxxf

F-3

Maintenance Port Parser Commands

54-0194 Rev. D

Table F-3
Operational Commands