beautypg.com

Appendix e - startup data sequences, Appendix e startup data sequences, E.1 tracvision lf sequences – KVH Industries LF User Manual

Page 54: E.1.1 system connected to ird data

background image

Appendix E
Startup Data Sequences

The data on the following pages presents the startup data
sequences registered by the TracVision LF/SF. The first part of
each section shows the sequences registered by a system that is
connected to an IRD low-speed data port. The second part of each
section shows the sequences registered by a system that is NOT
connected to an IRD low-speed data port. Both parts show two
routines. One is the standard, full initialization routine; the second
is that registered by TracVision LF/SF if it is turned on and
acquires the satellite via the “Instant On” operation (described in
Section 3, “Using Your TracVision LF/SF”). These sequences can be
recorded using the data port and a PC.

E.1

TracVision LF Sequences

E.1.1 System Connected to IRD Data

Standard Startup Sequence

?PGM

KVH TracVision LF Rev X - Version X.XX - Serial number XXXXXXXX

Limit Switch Test

Limit Switch Status:PASS------------------Pass is expected

*** Initializing IRD ***

IRD STATUS: PASS DSS -------------------PASS is expected with successful IRD identification

Saved Sat Pos: EL = 36.5

*** Initializing Rate Bias ***

+POS: 45.0 45.9 548

VEL_INDEX: Az = 1996, El = 2182 ----------Expected range is 1700-2300

RATE BIAS: PASS---------------------------Az & El values above are within valid ranges

*** Averaging Background Noise ***

+POS: 45.0 22.5 356

+POS: 135.0 20.0 362

+POS: 311.8 20.0 355

Average Noise Level = 381

Noise Threshold = 859

Saved Sat Pos: EL = 36.5

*** Entering Search Mode 1 ***

+POS: 27.0 20.1 354

+POS: 79.9 36.4 341

E-1

Startup Data Sequences

54-0194 Rev. D