Troubleshooting (cont.)

Symptoms

Probable Causes

Recommended Action

7.

Blower motor runs but no

air bubbles are formed.

A.

Blower air inlet is blocked.

A.

Clean blower air inlet.

B.

Airjets are clogged.

B.

Use a small between-the-teeth

dental brush and white vinegar.

Dip the brush in the vinegar, brush

the hole, rinse the brush in clean

water, and then use the wet rinsed

brush to rinse the hole.

C.

Check valve does not work.

C.

Replace the check valve.

D.

Blower motor does not work.

D.

Replace the blower motor.

E.

Control does not work.

E.

Replace the control.

8.

Blower motor operates,

air bubbles are formed,

zone controls work, but

variable speed feature

does not work.

A.

Blower air inlet is blocked.

A.

Clear blower air inlet.

B.

Loose, disconnected, or

damaged wiring harness.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary.

C.

User keypad does not work.

C.

Replace the user keypad.

D.

Blower motor does not work.

D.

Replace the blower motor.

E.

Control does not work.

E.

Replace the control.

9.

Blower motor won’t turn

off when the Power icon

on user keypad is

pressed.

A.

User keypad does not work.

A.

Replace the user keypad.

B.

Loose, disconnected, or

damaged wiring harness.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary.

C.

Control does not work.

C.

Replace the control.

10.

A zone does not produce

air bubbles but another

zone operates normally.

A.

Zone is not selected.

A.

Select the zone according to the

instructions in the

″Operating

Instructions

″ section.

B.

Butterfly valve does not work.

B.

Replace the butterfly valve.

C.

Loose, disconnected, or

damaged wiring harness.

C.

Check wiring for proper

connections. Replace the wiring

harness if necessary.

D.

User keypad does not work.

D.

Replace the user keypad.

E.

Control does not work.

E.

Replace the control.

11.

Surge mode does not

work.

A.

User keypad does not work.

A.

Replace the user keypad.

B.

Control does not work.

B.

Replace the control.

12.

Water spillage or damage

observed under the bath.

A.

Drain or overflow leaking.

A.

Repair or replace the drain

assembly according to the

manufacturer’s instructions.

B.

Wall, deck, and/or shower door

is improperly sealed.

B.

Apply silicone sealant at the seams

between the bath and the wall,

deck, or door.

C.

Cracked piping or air channels.

C.

Refer to the manufacturer.

13.

Bath does not purge

automatically.

A.

Level sensor wires are

disconnected.

A.

Connect the level sensor wires.

Chromatherapy (if equipped)

Symptoms

Probable Causes

Recommended Action

14.

Chromatherapy lights do

not work.

A.

Loose, disconnected or damaged

wiring/connections.

A.

Check wiring for proper

connections. Replace wiring if

necessary.

B.

Control does not work.

B.

Replace control.

15.

Chromatherapy does not

cycle.

A.

Chromatherapy harness

assembly does not work.

A.

Replace the chromatherapy harness

assembly.