Tk-8180, Adjustment – Kenwood TK-8180 User Manual

Page 41

background image

TK-8180

41

Item

Condition

Measurement

Adjustment

Specifications/Remarks

Test-

equipment

Unit

Terminal

Parts

Unit

Method

ADJUSTMENT

11. Max DEV

1) Adj item : [n DEV]

Power meter Rear

ANT

Front

[ ],[ ] 2.10kHz

±0.10kHz

adjust

Adjust : [

✳✳✳]

panel

panel

(According to the

AG : 1kHz/50mV at MIC terminal

larger +, –)

Deviation meter filter

Deviation

Front

Modular

LPF : 15kHz

meter

panel

MIC jack

HPF : OFF

Oscilloscope

• Narrow

2) Adj item : [nL DEV]

AG

[nC DEV]

→ [nH DEV]

AF VTVM

Adjust : [

✳✳✳]

PTT : ON

• Wide 4k

3) Adj item : [s DEV]

3.30kHz

±0.10kHz

Adjust : [

✳✳✳]

(According to the

PTT : ON

larger +, –)

• Wide 5k

4) Adj item : [w DEV]

4.20kHz

±0.10kHz

Adjust : [

✳✳✳]

(According to the

PTT : ON

larger +, –)

12. MIC

[Panel test mode]

Check

2.5~3.5kHz

sensitivity

1) CH-Sig : 1-1

check

AG : 1kHz/5mV at MIC terminal

(Wide 5k only)

PTT : ON

13. QT deviation 1) Adj item : [n QT]

Front

[ ],[ ] 0.35kHz

±0.05kHz

adjust

Adjust : [

✳✳✳]

panel

Deviation meter filter

LPF : 3kHz
HPF : OFF

• Narrow

2) Adj item : [nL QT]

[nC QT]

→ [nH QT]

Adjust : [

✳✳✳]

PTT : ON

• Wide 4k

3) Adj item : [s QT]

0.60kHz

±0.10kHz

Adjust : [

✳✳✳]

PTT : ON

• Wide 5k

4) Adj item : [w QT]

0.75kHz

±0.10kHz

Adjust : [

✳✳✳]

PTT : ON

14. DQT

1) Adj item : [n DQT]

0.35kHz

±0.05kHz

deviation

Adjust : [

✳✳✳]

adjust

Deviation meter filter

LPF : 3kHz
HPF : OFF

• Narrow

2) Adj item : [nL DQT]

[nC DQT]

→ [nH DQT]

Adjust : [

✳✳✳]

PTT : ON

• Wide 4k

3) Adj item : [s DQT]

0.60kHz

±0.10kHz

Adjust : [

✳✳✳]

PTT : ON

• Wide 5k

4) Adj item : [w DQT]

0.75kHz

±0.10kHz

Adjust : [

✳✳✳]

PTT : ON