beautypg.com

Removing and installing the lamp unit, Removing and installing the, Lamp unit – Sharp XG-F315X User Manual

Page 62: Regarding the lamp (continued), Warning

background image

58

Regarding the Lamp (Continued)

Removing and Installing
the Lamp Unit

• Make sure that you remove the lamp unit by

the handle. Do not touch the glass surface of
the lamp unit or the inside of the projector.

• To avoid injury to yourself and damage to the

lamp, make sure you carefully follow the steps
below.

• Do not loosen other screws except for the

lamp unit cover and lamp unit.

Press STANDBY/ON on the projec-
tor or STANDBY on the remote
control to put the projector into
standby mode.

• Wait until the cooling fan stops.

Warning!

• Do not remove the lamp unit from the projec-

tor right after use. The lamp and parts around
the lamp will be very hot and may cause burns
or injury.

Disconnect the power cord.

• Unplug the power cord from the AC

socket.

• Leave the lamp until it has fully cooled

down (about 1 hour).

Remove the lamp unit cover.

• Turn the projector over. Loosen the user

service screw (1) that secures the lamp
unit cover. Remove the lamp unit cover
(2).

Lamp unit
AN-F310LP

Info

Optional

accessory

AC socket

User service screw
(for lamp unit cover)

1

2

3

STANDBY/ON button

1

2