Maintenance indicators, Appendix – Sharp XG-F315X User Manual
Page 59
55
Appendix
Maintenance Indicators
About the lamp indicator
■ When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will be
displayed on the screen. When the percentage becomes 0%, it will change to
(red), the lamp will
automatically turn off and then the projector will automatically enter standby mode. At this time, the
lamp indicator will illuminate in red.
■ If you try to turn on the projector a fourth time without replacing the lamp, the projector will
not turn on.
About the temperature warning indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,
“
” will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp
will turn off and the temperature warning indicator will blink, the cooling fan will run, and then the projec-
tor will enter standby mode. After “
” appears, ensure you perform the measures described on
Lamp indicator
■ The warning lights (power indicator, lamp indicator and temperature warning indicator) on the
projector indicate problems inside the projector.
■ If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
red, and the projector will enter standby mode. After the projector has entered standby mode,
follow the procedures given below.
Temperature warning indicator
Power indicator
Red on
Green on
Red blinks
Green blinks
Green on
Green blinks
Red on
Off
Red on
Power indicator
Lamp indicator
Temperature warning
indicator
Indicators on the Projector
Normal (Standby)
Normal (Power on)
Abnormal (See page
Normal (Cooling)
Normal
The lamp is warming up.
The lamp is shut down abnormally or requires to be
changed. (See page
Normal
The internal temperature is abnormally high. (See page
Top View