beautypg.com

Display/setting ( continued ), Switch setting – SMC Networks ETHERNET/IP EX9-AC -7 User Manual

Page 10

background image

16

17

1

2

3

4

5

6

7

8

ON

1

0

IP address

192.168.0.X

1

0

1

0

1

0

1

2

0

0

1

1

1

1

3

0

0

0

0

1

1

4

0

0

0

0

1

1

Remote control *

1

X

3

2

1

14

DHCP mode *

2

SW1

Communication

setting

CLEAR/HOLD

Manual set up of
IP address *

3

SW1

5

0

1

1

1

1

1

6

-

-

0

1

-

-

7

-

-

-

-

0

1

SW1

Item

Communication

setting

Communication

speed

Communication

method

Contents

AUTO : The communication setting is automatically
selected.

MANUAL : The communication setting follows
the setting result by the switch No. 6 and 7.

Communicated at 10Mbps

Communicated at 100Mbps

Communicated at half duplex

Communicated at full duplex

SW1

8

0

1

Contents

The output signal is cleared when the communication error occurs.

The output signal is held when the communication error occurs.

Display/Setting ( continued )

*1 : Remote control (SW1 Dip Switches 1 to 4 off)

SMC's EX250 SI Unit will respond to the following Rockwell Automation BOOTP/DHCP

Server commands.

Enable DHCP

Selecting this function will enable the EX250 SI Unit to retrieve its boot information from

the BOOTP/DHCP Server. If DHCP is enabled the EX250 SI Unit will retrieve its boot

information during the next power up.

Disable BOOTP/DHCP

Selecting this function will disable the EX250 to retrieve its boot information from the

BOOTP/DHCP Server, and causes the EX250 to retain its current configuration during

the next power up.

*2 : DHCP Mode (SW1 Dip Switches 1 to 4 on)

The IP address is acquired via DHCP Server. The IP address is not saved and lost if the

power to the EX250 unit is cycled.

*3 : Hardware Addressing

The IP address range is 192.168.0.1-192.168.0.14.

Default settings

At the time of factory shipment, the product is in "Remote Control Mode" and set to

"Enable DHCP".

Switch setting

Open the switch protective cover and set the switches with a
sharp-pointed watchmakers screwdriver etc.

NOTE
1. Be sure to turn off the power before setting the switches.
2. Be sure to set these switches before use.
3. After setting the switch, close the switch protective cover and tighten the screws

with the proper tightening torque. (Tightening torque : 0.6N m)

NOTE
If the stored IP address of an EX250 is not known, please go to the "DHCP Mode" section.