Configuration
41
Siemens Building Technologies
Fire Safety & Security Products
01.2009
z
Scheduled Recording
Determine the recording condition: STOP, all day, schedule 1 or schedule 2 from
the recording schedule table for all days from Monday to Sunday.
z
Recording by Alarm
Configure "Alarm input setting" first.
Then select the recording format:
–
Record source: choose JPEG or MPEG4 format
–
Record frame
Set the number of images to be recorded immediately after an alarm occurs.
Images of the moment when an alarm occurs are not included.
1, 2, 5, 10, 30 and 60 frames can be selected if JPEG format selected. No
need for MPEG4 format.
–
Recording cycle
Set a time interval for alarm recording 1, 2, 5, 10, 30, 60, 90, 120 s can be
selected for JPEG format. No need for MPEG4 format.
–
Recording time:
If MPEG4 selected, please set the recording time to 2, 5, or 10 s.
z
Recording by Motion
Perform "Motion Detection Setting" first.
All the other settings are same as recording by alarm as above.
z
Recording by Network loss
Select network recording. After network loss, the network camera automatically
stores images based on your settings.