4 alarm, 1 external digital input 1 – Siemens DOME COLOUR CFMC1315-LP User Manual
Page 34
Configuration
34
Siemens Building Technologies
Fire Safety & Security Products
01.2009
7.4
Alarm
External alarms and motion sensors can be set. Connecting a sensor or other
device to the alarm input terminal notifies an alarm when the sensor detects a
trouble. For example, mounting a sensor on a door notifies an alarm each time the
door is opened. By setting the motion sensor to activate, an alarm is notified by
detecting a change in a screen.
One Alarm input1 terminal is indicated on external cable. You need to define some
parameters before u sing the alarm function.
7.4.1
External digital input 1
z
Set an "Alarm Input"
ON: Detects an external alarm.
OFF: Does not perform alarm detection.
Î
The following functions will be enabled if “ Alarm Input” is set to “ON”
z
Set "Input type" for alarms
Normally Opened (NO): A dry-contact detecting way, opened if nothing occurs
but closed in case of an alarm.
Normally Closed (NC): A dry-contact detecting way, closed if nothing occurs but
open in case of an alarm.
z
Set "TEXT Enable" for alarms
A noticeable message of alarm can be displayed on screen if this item is set to
“ON”.
z
Enter "Text" for alarm message
Max 24 characters can be entered.
z
Set "Audio out" for alarm message
Audio alarm message can be sent to external speaker if this item set to “ON”.