Troubleshooting / Decommissioning and disposal

Red LED display is lit, “Error” appears in the display and “FAN” is flashing

Cause

Fault related to fan in pump housing.

Remedy

̈ Check fan and replace if necessary.
̈ Press the P key (reset function).

Red LED display is lit, “Error” appears in the display and “SYSTEM” is flashing

Cause

Controller fault.

Remedy

̈ Disconnect the pump from the mains and reconnect.

If the error message continues, send the pump back to ProMinent.

Red LED lights up, “Error” appears in the display and “Menu” flashes.

Cause

Stroke buffer full

Remedy

̈ Rectify fault
̈ Press P key (Make a note of what effect this has on your process).

All other Errors

Please contact your ProMinent branch or representative!

Fault Signals

Yellow LED display is lit

Cause

Liquid level in chemical storage tank has reached “liquid level low, stage 1”.

Remedy

̈ Fill chemical storage tank.

Yellow LED Display is lit and “calib” flashes

Cause

The pump is calibrated and the stroke length deviates by more than ±10 % from the value at
the time of calibration.

Remedy

̈ Reset the stroke length or calibrate the pump again to the desired stroke length.

10

Decommissioning and disposal

Decommissioning

WARNING

• EX-pump only: metering pumps and their periphery must be maintained or

decommissioned by qualified or authorised personnel!

• For all metering pumps for metering inflammable media applies: Starting up and

emptying only supervised by a competent person.

• When decommissioning the pump, ensure that all dirt and chemicals are cleaned from

the housing and particularly the liquid end.

• Always take suitable precautions when using hazardous chemicals!

• Ensure that the equipment is de-pressurised!

̈ Disconnect the pump from the mains.
̈ Empty the liquid end by placing the pump on its head and allowing the chemical to drain

out.

̈ Rinse the liquid end with a suitable material, thoroughly rinse the liquid end after use with

hazardous materials!

If decommissioning is only temporary, maintain the correct storage conditions:

Storage temperature:

-10 to +50 °C

Air humidity:

< 92 % relative humidity

Disposal

WARNING

Spring under tension!

Take particular care when disassembling the pump as the return spring (Item 5, Chapter 2.2)
is under considerable mechanical tension!

IMPORTANT

Observe your locally applicable regulations (particularly with regard to electronic scrap and
gear oil)!