Tc t n c, 02 1 t e s – SIGMA S2Ba User Manual
Page 48

Page 48
Pr
o
Minent
®
Dulcodes UV-Desinfektionsanlage
Settings
In the “contact - identity code: external with external pulse control” you can enter the number
of pulses after which a stroke should be carried out. “Contact - identity code: external with
external pulse control” is intended for small dosing quantities.
P
P
P
P
Continuous
display
t
c
t
n
c
Set
n
o
Set
Mem
Contact
0
Set
Mem
Contact
0
2
1
t
e
s
The number of strokes per pulse depends upon the factor, which you can enter. This allows
you to vary to a certain extent the input pulses by a factor of 1.01 to 99.99 and/or reduce by a
factor of 0.01 to 0.99:
“Number of strokes activated = factor x number of input pulses”
Examples
Factor
Pulse (sequential)
Stroke number (sequential)
Increase
1
1
1
2
1
2
25
1
25
99.99
1
99.99
1.50
1
1.5 (1 / 2)
1.25
1
1.25 (1 / 1 / 1 / 2)
Reduction
1
1
1
0.50
2
1
0.10
10
1
0.01
100
1
0.25
4
1
0.40
2.5 (3 / 2)
(1 / 1)
0.75
1.33 (2 / 1 / 1)
(1 / 1 / 1)
Explanation of increase
At a factor of 1
For every 1 pulse, 1 stroke is activated
At a factor of 2
For every 1 pulse, 2 strokes are activated
At a factor of 25
For every 1 pulse, 25 strokes are activated
Explanation of decrease
At a factor of 1
After 1 pulse, 1 stroke is activated
At a factor of 0.5
After 2 pulses, 1 stroke is activated
At a factor of 0.1
After 10 pulses, 1 stroke is activated
At a factor of 0.75
After 2 pulses, 1 stroke is activated,
then after 1 pulse, 1 stroke is activated,
then after 2 pulses, 1 stroke is activated etc.