beautypg.com

SIGMA S2Ba User Manual

Page 32

background image

Page 32

Pr

o

Minent

®

Dulcodes UV-Desinfektionsanlage

NOTE

The tightening torque of the liquid end screws should be rechecked after 24 hours of
operation.

The tightening torques of the liquid end screws should be checked every 3 months for the
PVT material version.

Start-up/Maintenance

Fig. 13

approx. 300 g

Brass rod 9 mm diam. x approx. 200 mm

Fig. 12

GUIDELINE ON VALVE INSTALLATION

In the case of suction problems during installation, place the valves on a firm surface and tap the
PTFE ball seat disk lightly with a brass rod and a hammer weighing about 300 g. Let the valves
operate in the wet state.

NOTE

• If suction problems with the pump or leakage at the overcurrent valve are encountered,

first clean the ball and the ball seat disc.

• For media containing particles larger than 0.3 mm it is absolutely essential to install a

filter in the suction line.