beautypg.com

Appearance view installation information, Auto touch control panel, Oven – Sharp R-2397 User Manual

Page 5

background image

3

R-2397

APPEARANCE VIEW

INSTALLATION INFORMATION

When this commercial microwave oven is installed near other commercial electrical appliances, connect a lead wire
to each equivalent potential terminal with equipotential marking between them (insert a lead wire between a washer and
an earth angle, and screw them), as shown in Fig. A-1, to make sure that they are at equivalent potential.
If any lead wire is not connected between them, when person touch them he/she will get a electric shock.

COMMERCIAL MICROWAVE OVEN

OTHER COMMERCIAL
ELECTRICAL APPLIANCE

Lead wire

Equipotential marking

Earth angle
(Equivalent potential terminal)

Equivalent
potential terminal

Screw

Washer

Lead wire

Figure A-1

DISPLAY AND INDICATORS
Check indicators after the oven starts to
confirm the oven is operating as desired.

1. Heating indicator

This indicator shows cooking in progress.

2. Memory number indicator

3. Defrost indicator

4. Check mode indicator

5. Power level display

6. Time display

7. Filter indicator

8. Double quantity mode indicator

9. 3rd. stage indicator

10. 2nd. stage indicator

11. 1st. stage indicator

OPERATING KEYS

12. DOUBLE QUANTITY key

13. DEFROST key

14. NUMBER keys

15. MANUAL/ REPEAT key

16. STOP/CLEAR key

17. MICROWAVE POWER SETTING key

18. START key

19. SET key

20. VOLUME key

21. CHECK key

AUTO TOUCH CONTROL PANEL

1. Control panel

2. Hole for safety door latches

3. Ceramic floor

4. Splash cover

5. Oven light

6. Air intake filter

7. Air intake openings

8. Oven cavity

9. Door seals and sealing surfaces

10. Door hinges

11. Oven door with see-through window

12. Door safety latches

13. Door handle.

14. Outer cabinet

15. Removable cover over oven light bulb

16. Air vent openings

17. Power supply cord

18 Mounting plate

19 Screw for mounting plate

OVEN

1

2

3

4

5

7

6

8

9

10

11

12

13

15

16

14

18

19

17

DEF CHECK

POWER

%

DOUBLE

ON

NUMBER

1

2

3

16

18

20

13

5

2
1

12

15

17

19

21

11

10

FILTER

3 4

6

7
8
9

x2

1

2

3

4

5

6

7

8

9

0

11

12

13

14

15

16

17

18

19

20

14