1. CARRY OUT 3D CHECKS.
2. Remove four (4) screws holding the upper and lower

oven hinge to the oven cavity.

3. Remove door assembly with upper and lower oven

hinges by pulling it forward.

4. On re-installing new door assembly, secure the upper

and lower oven hinges with the four (4) mounting
screws to the oven cavity. Make sure the door is
parallel with bottom line of the oven face plate and the
latch head pass through the latch holes correctly.

5. CARRY OUT 4R CHECKS.
Note:

After any service to the door, the approved
microwave survey meter should be used to assure
in compliance with proper microwave radiation
standards. (Refer to Microwave Measurement
Procedure.)

DOOR ADJUSTMENT

When removing and/or loosening hinges such as in door
replacement, the following adjustment criteria are taken.
Door is adjusted to meet the following three conditions by
keeping screws of hinge loose.
1. Adjust door latch heads at a position where they

smoothly catch the latch hook through the latch holes.
Refer to latch switch adjustments.

2. Deviation of the door alignment from horizontal line of

cavity face plate is to be less than 1.0mm.

3. The door is positioned with its face depressed toward

the cavity face plate.

4. Reinstall outer case and check for microwave leakage

around the door with an approved microwave survey
meter. (Refer to Microwave Measurement Proce-
dure.)

UPPER
OVEN
HINGE

LOWER
OVEN
HINGE

DOOR
ASSEMBLY

LATCH HEADS

OUTER CASE
CABINET

Figure C-5. Door Assembly Replacement and Adjustment

CHOKE COVER REMOVAL

1. Insert an iron plate (thickness of about 0.5mm or flat

type screw driver to the gap between the choke cover
and door panel as shown figure to free the engaging
part. The protect sheet may be used not to damage
the door panel.

2. Lift up the choke cover, now cove is free.

DOOR REPLACEMENT AND ADJUSTMENT

DOOR
PANEL

CHOKE
COVER

FLATE TYPE
SCREW DRIVER

PROTECTION
BY TAPE

LOWER
OVEN HING

UPPER
OVEN HING

Figure C-6. Choke Cover Removal

DOOR COMPONENTS REMOVAL

Remove the door assembly, referring to from item 1
through item 3 of “DOOR REPLACEMENT”.
1. Place the door assembly on a soft cloth with facing up.

(UPPER AND LOWER OVEN HINGE REMOVAL)

2. Remove the choke cover, referring to “CHOKE COVER

REMOVAL”.

3. Release the oven hinges from the door panel.
4. Now, the oven hinges are free.

(DOOR HANDLE REMOVAL)

5. Remove the two (2) screws holding the door handle to

door.

6. Remove the door handle from the door panel.

(UPPER AND LOWER LATCH HEADS REMOVAL)
7. Remove the door release lever from the door assem-

bly.

8. Remove the three (3) screws holding the joint plate to

the door panel.

9. Release the latch spring from the tab of the joint lever

and joint plate.

10.Release the latch heads from joint lever and joint plate.
11.Now, the latch heads are free.

(DOOR FRAME REMOVAL)

12.Set the four (4) tabs of the door frame upright.
13.Remove the door frame from the door panel. Now,

door frame is free.

(DOOR GLASS REMOVAL)

14.Remove the four (4) screws holding the two (2) outside

window fixing plates to the door panel.

15.Now, the door glass is free.