beautypg.com

Control panel assembly and control unit removal, How to release the positive lock, Connector – Sharp R-2397 User Manual

Page 28

background image

26

R-2397

CONTROL PANEL ASSEMBLY AND CONTROL UNIT REMOVAL

CONTROL PANEL ASSEMBLY REMOVAL

The complete control panel should be removed for re-
placement of components. To remove the control panel,
proceed as follows:
1. CARRY OUT 3D CHECKS.
2. Remove the air intake filter assembly from the base

plate.

3. Remove two (2) screws holding the control panel to

the base plate.

4. Pull down the control panel and remove it forward.
5. Disconnect two connectors (A), (B), (D), (H) and TAB

terminal (TAB1,2,3,4) from the control unit.

6. Now the control panel assembly is free.

CAUTION FOR TOUCH CONTROL PANEL REMOVAL
1) Hold the lower end (Position A, Fig. 1) of the touch

control panel assembly firmly while sliding it down and
toward you.

DO NOT FORCE THE CONTROL UNIT TO SLIDE
DOWN DURING REMOVAL. THIS MAY CAUSE DAM-
AGE TO THE CONTROL UNIT BY HITTING A RELAY
(RY-4) OR THE TAB TERMINALS LOCATED AT THE
FRONT OF THE OVEN CAVITY.

2) If the Touch Control Panel is hard to remove;
(1) Insert a flat head screw driver into space B . (Fig. 1)
(2) Rotate the screwdriver clockwise while holding posi-

tion C of the Touch Control Panel. (Fig. 2)

TO AVOID DAMAGE TO TOUCH CONTROL PANEL,
COVER THE TIP OF SCREWDRIVER WITH TAPE.

(3) Re-solder the Relay (RY-4) prior to reinstalling the

Touch Control Panel.

B

A

C

B

Fig. 1

Fig. 2

TOUCH CONTROL PANEL

SCREW DRIVER

Replacement of individual component is as follows:

CONTROL UNIT AND CONTROL PANEL FRAME
(WITH KEY)

7. Remove two (2) screws holding the control panel

mounting angle to the panel frame.

8. Lift up the control panel mounting angle from the panel

frame.

9. Disconnect connector (G) from the control unit by

pushing the hooks of cable holder inwardly.

10.Remove four (4) screws holding the control unit to the

panel frame assembly.

11.Push down the right side two (2) hooks fixing the

control unit to the panel frame assembly, and lift up the
control unit upward.

12.Now, the control unit and control panel frame (with

key) are free.

CAUTION:
At installing control panel unit assembly to main

body set:

1. Ensure the installation of wiring-related parts with-

out negligence.

2. When inserting key cable to main body set, ensure

them free from caught-in trouble. In addition, when
installing the control panel assembly to base plate
with screws, be sure of pushing the control panel
unit upward to fix with screws firmly.

3. Do not allow any wire leads to come near the

varistor works, because it will explode and the
wire leads near by the varistor will be damaged.

NOTE: 1. Before attaching a new key unit, remove

remaining adhesive on the control panel frame
surfaces completely with alcohol.

2. When attaching the key unit to the control

panel frame, adjust the upper edge and right
edge of the key unit to the correct position of
control panel frame.

3. Stick the key unit firmly to the control panel

frame by rubbing with soft cloth not to scratch.

HOW TO RELEASE THE POSITIVE LOCK

®

CONNECTOR.

Procedure
1. Pushing the lever of positive lock

®

connector.

2. Pull down the connector from the terminal.
3. Now, the connector is free.

Note: If the positive lock

®

has a insulation sleeve, first

remove it. If you do not so, you can not push the
lever of positive lock

®

.

CAUTION: The positive lock

®

terminal can not be dis-

connected by only pulling. Because once
you (Service personnel) have connected the
positive lock

®

connector to the terminal, the

positive lock

®

connector has been locked.

Figure C-2. How to release the positive lock connector.

Terminal

Push

Pull down

1

2

Lever

Positive lock®