Maintenance indicator

Problem

Cause

Possible solution

Temperature

warning

indicator

Normal

Abnormal

Off

Red on
(Standby)

The internal
temperature is
abnormally high.

Abnormal

• Blocked air intake

• Relocate the projector to an area

with proper ventilation (see page

8

).

• Cooling fan break-

down

• Internal circuit failure
• Clogged air intake

• Take the projector to your nearest

Sharp Authorized Projector Dealer
or Service Center (see page

66

)

for repair.

• Clean the exhaust and intake

vents. (See page

55.

)

Lamp

indicator

Red on
(Standby)

The lamp does
not illuminate.

• Burnt-out lamp
• Lamp circuit failure

• Carefully replace the lamp. (See

page

61

.)

• Take the projector to your nearest

Sharp Authorized Projector Dealer
or Service Center (see page

66

)

for repair.

• Please exercise care when

replacing the lamp.

• Securely install the lamp unit cover.

Red on

Time to change
the lamp.

• Remaining lamp life

becomes 5% or less.

Green on

Green blinks

when the lamp

is warming up

Info

• If the temperature warning indicator illuminates and the projector enters the standby mode, check whether

any of the ventilation holes are blocked (see page

8

) and then try turning the power back on. Wait until the

projector has cooled down completely before plugging in the power cord and turning the power back on.
(At least 10 minutes.)

• If the power is turned off for a brief moment due to power outage or some other cause while using the

projector, and the power supply recovers immediately after that, the lamp indicator will illuminate in red
and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace the power
cord in the AC outlet and then turn the power on again.

• The cooling fan keeps the internal temperature of the projector constant and this function is controlled

automatically. The sound of the cooling fan may change during operation because the fan speed may
change and this is not a malfunction.

The lamp does
not illuminate.

• The lamp is shut

down abnormally.

• Disconnect the power cord from

the AC outlet, and then connect it
again.

Power

indicator

Green on/

Red on

Green blinks

(Cooling)

Red blinks

The power
indicator blinks
in red when the
projector is on.

• If the power indicator blinks even

when the covers are securely
installed, or if the cooling fan does
not run normally, then contact your
nearest Sharp Authorized
Projector Dealer or Service Center
(see page

66

) for advice.

• The filter cover, lamp

unit cover or lens
housing cover is
open.

• Cooling fan break-

down