Appendix C

Procedure to Configure Remote Electronic Track & Hold Board for 220/240 VAC Operation

The board is factory shipped as 110/120 VAC. Perform the following steps to convert the board for use with
220/240 VAC.

1. Remove the zero-ohm resistor jumpers at W1, W3, W4, W6, W7 and W9 on solder side of the remote

electronic track & hold board. Refer to Figure C1.

2 . Install jumpers at W2, W5 and W8 on solder side. Use zero-ohm jumpers or 22 AWG insulated wire.

FIGURE C1 - Remote Electronic Output Board Arrangement


SENTRY

Equipment Corp • P. O. Box 127 • Oconomowoc, WI 53066 • 262/567-7256 • FAX: 262/567-4523

Web: www.sentry-equip.com • e-mail: [email protected]