1 selecting the ethernet framing type, 2 assigning a slot number, Selecting the ethernet framing type – Schneider Optics Web Embedded Server User Manual
Page 31: Assigning a slot number

Installing and Configuring the Module
840 USE 115 00 Version 1.0
21
2.4.1
Selecting the Ethernet Framing Type
You may choose between Ethernet II and IEEE 802.3, depending on your system.
The default choice is Ethernet II.
If you are using the configuration extension to change the framing to IEEE 802.3,
do not forget to designate the backplane slot number on the next line. Without the
slot number, the system will not record the change in framing.
2.4.2
Assigning a Slot Number
To activate the configuration extension screen, you must enter the backplane slot
number on the second line. This is the slot where you have mounted or intend to
mount the Ethernet web embedded serve module. The slots are numbered from left
to right, from one to x.
Note: If you do not enter the slot number, the system will ignore any other data
you enter on this screen.
Figure 14 Configuration Extension Screen
modsoft
F1
Hex
PgDn/Up to next/prev Screen
F2
F3
F4
F5
F6
F7
F8
F9
Quit
Dec
Bin
Goto
Quantum TCP/IP CONFIG EXT.
Screen 1 / 6
Lev 8
OFF
Ethernet Framing Type:
Internet Address:
Default Gateway Address:
Quantum Backplane Slot:
(B4) : 0
DEC
(B3) : 0
DEC
(B2) : 0
DEC
(B1) : 0
DEC
B4. B3. B2. B1
Note: 000.000.000.000
represents the TCP/IP
Board Default
Internet Address
G4. G3. G2. G1
Note: 000.000.000.000
represents the TCP/IP
Board Default
Gateway Address
(G4) : 0
DEC
(G3) : 0
DEC
(G2) : 0
DEC
(G1) : 0
DEC
SubNetwork MASK: FFFFFF00
HEX
Ethernet II
0