1-2
MSW-A2000
MSW-A2000P
n
AC power supply is required a capacity which is commen-
surate with rush current.
If the capacity of the AC power supply is not enough, the
breaker of AC power of a supply side may operate or this
unit may not operate normally.
1-4-2. Power Cord
w
Use the specified power cord only when connecting the
AC power.
Never use a damaged power cord.
For customers in the U.S.A. and Canada:
1 Power cord (approx. 2.4 m) ! 1-557-377-11
2 Plug holder (Brown)
3-613-640-01
Please contact your local Sony Sales Office/Service
Center.
For customers in the United Kingdom:
1 Power cord DK-2401(UK) (approx. 2.4 m)
2 Plug holder (Brown)
3-613-640-01
Plug holder is included in DK-2401(UK).
For customers in Europe except the United Kingdom:
1 Power cord DK-2401(AE) (approx. 2.4 m)
2 Plug holder (Brown)
3-613-640-01
Plug holder is included in DK-2401(AE).
If the unit is used in the area except above, please contact
your local Sony Sales Office/Service Center.
1-3. Operating Conditions
1-4. Power Supply
1-3. Operating Conditions
c
Good air circulation is essential to prevent internal heat
build-up. Place the unit in location with sufficient air
circulation.
Do not block the ventilation holes of the cabinet and the
front and rear panels.
Operating temperature: 5
dC to 40 dC
Operating humidity:
25 % to 80 %
(Condensation not allowed)
Storage temperature:
_20 dC to 60 dC
Locations to avoid:
. Areas where the unit will be exposed to direct sunlight
of any other strong lights.
. Areas near heat sources.
. Dusty areas or areas subject to vibration.
. Areas with strong magnetic field.
. Areas with much electrical noise.
. Areas with much static electricity.
. Areas that is impossible to find a specified room for
installation.
(Refer to “1-5. Installation Space” page 1-3.)
. Areas windtight.
Tilt allowance:
Within 30
d
Do not slant the front and rear of the
unit more than 30
d.
c
Fix the unit securely to avoid drop when the unit is operat-
ed at not-horizontal place.
1-4. Power Supply
1-4-1. Voltage and Power Requirements
w
Be sure to operate the unit within the range of following
power voltage.
Power voltage:
AC 100 to 240 V
±
10 %
Power frequency:
50 Hz or 60 Hz
Power consumption: 2A (200 W)
(Without the optional kit.)
Rush current:
Power voltage 100 V IN; 10 A
Power voltage 240 V IN; 20 A
This unit’s power line has a switching regulator.
AC inlet
2
1
2
AC inlet
1
AC inlet
2
1