15-1. settings for time code, 15-2. vtr constant values settings of editor – Sony MSW-A2000P User Manual
Page 29

1-23
MSW-A2000
MSW-A2000P
1-15. Settings and Adjustment when External Equipment is Connected
1-15-1. Settings for Time Code
To set the TIME CODE, open the P1 page (TCG/TCR SETTING) on the function screen.
When Editing with an Editor (BVE-2000, etc.) Capable of the 1st Edit
When MSW-A2000/A2000P is used by connecting to an editor, set as follows.
Button
Item (Display)
Setting
F1
TCG INT/EXT (TCG)
INT
F2
TCG PRESET/REGEN (TCG)
PRESET
F3
TCG RUN (RUN)
FREE
When Editing with Direct Machine-to-Machine (VTR to VTR)
n
The setup menu ITEM-610: REGEN CONTROL MODE setting data must be set to “AS&IN”.
Button
Item (Display)
Setting
F1
TCG INT/EXT (TCG)
INT
F2
TCG PRESET/REGEN (TCG)
PRESET
F3
TCG RUN (RUN)
REC
1-15-2. VTR Constant Values Settings of Editor
Set the VTR constant values according to the table below when the editor which needs the setting of VTR
constant values is connected. Moreover, the change of VTR constant values are required when the 525/
625 system is switched by setup menu of this unit.
VTR CONSTANT 1
VTR CONSTANT 2
Model
525/625
Data No.
Data No.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
MSW-A2000
525/60
B0
61
00
96
07
07
03
8A
*
0A
07
FB
00
81
3D
FF
5A
625/50
B1
61
00
7D
07
07
03
8A
*
0A
06
FB
00
83
4B
FF
4B
MSW-A2000P
525/60
B0
61
00
96
07
07
03
8A
*
0A
07
FB
00
81
3D
FF
5A
625/50
B1
61
00
7D
07
07
03
8A
*
0A
06
FB
00
83
4B
FF
4B
*: Set the data of No.8 of the VTR CONSTANT 1 to “0A” for the following editors.
. BVE-900 ROM versions earlier than 1.08
. BVE-600 ROM versions earlier than 1.01
n
When remote-controlling this unit by the editor, set the setup menu ITEM-401: FUNCTION MODE
AFTER CUE-UP to “STOP”.
1-15. Settings and Adjustment when External Equipment is Connected