Figure 45, Environmental classes – Sierra Wireless AIRPRIME WISMO218 User Manual
Page 91
WA_DEV_W218_PTS_002
Rev 006
April 29, 2010
91
Product Technical Specification &
Customer Design Guidelines
Technical Specifications
not affect the ability of the AirPrime WISMO218 to connect to the cellular network and be fully
functional, as it does within the Class A range.
The detailed climatic and mechanics standard environmental constraints applicable to the AirPrime
WISMO218 are listed in the table below:
WISMO218
ENVIRONNEMENTAL CLASSES
TYPE OF TEST
STANDARDS
STORAGE
TRANSPORTATION
OPERATING (PORT USE)
Class 1.2
Class 2.3
Class 7.3
Cold
IEC 68-2.1
-25° C 72 h
-40° C 72 h
-20° C (GSM900) 16 h
Ab test
-10° C (GSM1800/1900) 16h
Dry heat
IEC 68-2.2
+70° C 72 h
+70° C 72 h
+55° C 16 h
Bb test
Change of temperature
IEC 68-2.14
-40° / +30° C 5 cycles
-20° / +30° C (GSM900) 3 cycles
Na/Nb test
t1 = 3 h
-10° / +30° C (GSM1800/1900):
3 cycles t1 = 3 h
Damp heat
IEC 68-2.30
+30° C 2 cycles
+40° C 2 cycles
+40° C 2 cycles
cyclic
Db test
90% - 100% RH
90% - 100% RH
90% - 100% RH
variant 1
variant 1
variant 1
Damp heat
IEC 68-2.56
+30° C 4 days
+40° C 4 days
+40° C 4 days
Cb test
Sinusoidal vibration
IEC 68-2.6
5 - 62 Hz : 5 mm / s
Fc test
62 - 200Hz : 2 m / s2
3 x 5 sweep cycles
5 - 20 Hz : 0.96 m2 / s3
10 -12 Hz : 0.96 m2 / s3
Random vibration
IEC 68-3.36
20 - 500Hz : - 3 dB / oct
12 - 150Hz : - 3 dB / oct
wide band
Fdb test
3 x 10 min
3 x 30 min
Figure 45.
Environmental classes